Deployment in the European Union – CE Mark 

This Product carries CE Mark: 

 

Declaration of Conformity for radio equipment under the scope of 
Directive 2014/53/EU (RED) statement 

The Radio Equipment Directive 

2014/53/EU

 (RED) establishes a regulatory 

framework for placing radio equipment on the market. It ensures a Single Market for 

radio equipment by setting essential requirements for safety and health, 
electromagnetic compatibility, and the efficient use of the radio spectrum 
Hereby, Tarana Wireless Inc. declares that the equipment documented in this 
publication is in Compliance with the essential requirements and other relevant 
provisions of Directive 2014/53/EU (RED). 
The technical documentation as required by the Conformity Assessment procedure 
is kept at Tarana Wireless Inc. location which is responsible for this product. For 

more information please contact your local Tarana Wireless Inc. Customer Service 
or Sales representative.  
This declaration is only valid for G1 systems (hardware, software, and firmware) that 

are provided for use within the EU.  If this equipment is used in a manner not 
specified by Tarana Wireless Inc. (including use of unsupported software or 

firmware), it may result in the equipment no longer being compliant with the 
regulatory requirements. 

Tarana Products described above could face some restrictions to operate 
in the following Countries: 

 

AT 

BE 

BG 

HR 

CY 

CZ 

EE 

FI 

EL 

FR 

IT 

LV 

LT 

LU 

NL 

PL 

RO 

SK 

ES 

SW 

UK 

DE 

CH 

LI 

NO 

IC 

TR 

 

 

This Product meets International guidelines for human exposure to RF 
fields 

Tarana Wireless systems are designed to be operated as to avoid contact with the 

antennas by the end user. It is recommended to install the system in a location 
where the antennas can remain at least a minimum distance as specified from the 

user in accordance to the regulatory guidelines which are designed to reduce the 
overall exposure of the user or operator.  To meet radiation exposure requirements, 
these devices should be installed at a minimum distance of 0.7083 from people or 
animals. 

E-Field Limit (V/m) 

Distance (m) 

61 

0.7083 

G1 product complies with RF Exposure Requirements: EN 62311 

Eco-Environmental Statements 

 

Electronic products and batteries bearing or referencing the symbols shown above 
shall be collected and treated at the end of their useful life, in compliance with 
applicable European Union and other local legislation. They shall not be disposed 

of as part of unsorted municipal waste. Due to materials that may be contained in 
the product and batteries, such as heavy metals, the environment and human 
health may be negatively impacted as a result of inappropriate disposal.  

WEEE, REACH and RoHS Compliance  

Tarana Wireless products have been reviewed, analyzed and found to be following 
the European Union (EU) directive for Waste Electrical and Electronic Equipment 

(WEEE) WEEE Directive 2012/19/EU, with the EU directive for the Restriction of 
Hazardous Substances (RoHS)

 

RoHS Directive 2011/65/EU and REACH Regulation 

(EC) No 1907/2006. 
WEEE Collection Programs in the U.S. and EU at end of product life (EOL), customers 
are requested to contact Tarana Wireless to plan for WEEE collection/disposal of 

their products. The Tarana collection center in the U.S. is at the following address: 
Tarana Wireless Inc. 590 Alder Drive, Milpitas, CA 95035 Telephone: 408-351-4085 
Contact: compliance@taranawireless.com

 

 

Summary of Contents for G1 RN

Page 1: ...TaranaG1RNManual ...

Page 2: ...a Statements 7 Deployment in the European Union CE Mark 8 Preparation 10 Tools Required 10 Tarana Hardware and Peripherals 10 Customer Supplied Equipment 10 Physical Installation 11 Preparing the RN 11 Wall or Surface Mounting the Elevation Bracket 12 Pole Mounting the Elevation Bracket 12 Installing the RN 13 Powering Up the RN 14 Warranty 15 NOTE For the most up to date instructions please downl...

Page 3: ...port when no fiber is connected therefore avoid exposure to laser radiation and do not stare into open apertures FCCInformation The FCC occupational controlled limit for maximum permissible exposure MPE is 5 mW cm2 It is estimated that the maximum power density at the radome is 1 25 mW cm2 which is below the FCC MPE limit Since the power density for an occupational controlled environment is less t...

Page 4: ... to this equipment that are not in accordance with the provisions of this User Guide the Installation Guide or other supplementary documentation may result in personal injury or damage to the equipment and may void the equipment warranty AVERTISSEMENT Tout réglage ou modification faits à cet équipement hors du cadre édicté par ce guide d utilisation ou par toute autre documentation supplémentaire ...

Page 5: ... to bend them beyond their minimum bending radius Protect cover unconnected optical fiber connectors with dust caps Grounding Connections Reliable grounding of the G1 chassis must be maintained Mains Power Supply Routing G1 DC power is not to be routed with any AC mains power lines They are also to be kept away from any power lines which cross them Maximum Ambient Temperature The maximum ambient t...

Page 6: ... 2013 08 IP X7 EN 62368 1 2014 2nd Edition IEC EN 60950 22 Immunity EN61000 4 5 Level 4 AC Surge Immunity EN61000 4 4 Level 4 Electrical Fast Transient Burst Immunity EN61000 4 3 Level 4 EMC Field Immunity EN61000 4 2 Level 2 ESD Immunity Radio Approvals FCC Part 15 Subpart E 15 407 RSS 192 RSS 197 RSS 199 EN 302 326 2 EN 302 502 EMI and susceptibility FCC part 15 207 15 209 ICES 003 RSS Gen CAN I...

Page 7: ...ergy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correc...

Page 8: ...ce including interference that may cause undesired operation of the device Le produit final doit être installé par un professionnel Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada IC avertissements d exposition RF Pour satisfaire les exigencies d IC en ce qui a trait aux expositions aux RF pour RF dispositifs de transmission les distances suivantes doit être mainten...

Page 9: ...s Tarana Wireless systems are designed to be operated as to avoid contact with the antennas by the end user It is recommended to install the system in a location where the antennas can remain at least a minimum distance as specified from the user in accordance to the regulatory guidelines which are designed to reduce the overall exposure of the user or operator To meet radiation exposure requireme...

Page 10: ... Ova oprema je u skladu s osnovnim zahtjevima i drugim relevantnim odredbama Direktive 2014 53 EU English This equipment is in compliance with essential requirements and other relevant provisions of Directive 2014 53 EU Български Bulgarian Това оборудване е в съответствие с основните изисквания и съответващите разпоредби на Директива 2014 53 EU Cesky Czech Toto zařízení je v souladu se základními ...

Page 11: ...are and Peripherals RN radio unit RN mounting kit o 1pcs RN chassis bracket o 1pcs RN elevation Bracket o 8pcs M5 flanged head screw with thread lock o 2pcs Wormdrive clamps Single hole ground lug Passive PoE injector with power cord 1 m Ethernet cable Customer Supplied Equipment Ethernet cable shielded CAT5e CAT6 RJ45 connectors Grounding wire 14 AWG Earthing hardware Lightning and surge protecti...

Page 12: ...hat will not damage the plastic radome Step 2 Place the chassis bracket onto the back of the RN and locate it onto the 4 threaded holes Step 3 Using an 8mm hex socket install the four screws and gradually torque them in a crossing pattern to the specified torque value of 6 N m 4 5 ft lb Step 4 Partially install one screw on each of the elevation attachment tabs of the chassis bracket in the locati...

Page 13: ... in diameter can be used with the bracket without issue Do not attempt to use fasteners smaller than 6mm and never modify the elevation bracket by drilling for larger than 8mm fasteners as it will damage the corrosion protection of the finish Step 3 Install the elevation bracket with its elevation tabs facing outward and oriented as shown PoleMountingtheElevationBracket Step 1 Route the opened scr...

Page 14: ...nd around the terminated RJ45 connector and cable Step 5 Carefully plug the RJ45 connector into the RN making sure there is an audible click made by the connector properly seating into RJ45 receptacle on the main PCB inside the RN enclosure If the click is not heard a slight pull on the Ethernet cable is sufficient to check if the cable has been properly seated or not DO NOT FORCIBLY pull on the E...

Page 15: ...rana POE injector apply power to Ethernet cable Step 2 Verify LED operation Step 3 Once the RF link is established optimize alignment using RN local WebUI Step 4 Torque the four screws used on the elevation attachment tabs to 6 N m 4 5 ft lb Step 5 Run final checks a Authentication b Internet connectivity c Internet speed test ...

Page 16: ...r implied conditions representations and warranties including without limitation any implied warranty or condition of merchantability fitness for a particular purpose non infringement satisfactory quality non interference accuracy of informational content or arising from a course of dealing law usage or trade practice are hereby excluded to the extent allowed by applicable law and are expressly di...