SF-2200H Flame / Plasma CNC Cutting System Operating Manual
22
Section 7 Diagnose Function
Under system main menu, press F4 to enter Diagnose function menu, shown as below:
The system diagnose function can check the signal of input/output whether normal or not.
1
.
OUTPUT: There are 16 output ports, move cursor and change the value( from
‘0’ to ‘1’ or ‘1’ to ‘0’) to
change the level state:
1: high level;
0: low level.
2
.
INPUT: There are 16 input ports. 1: enable, 0: disable. About the input ports
’ definition, please refer 9.3.
图 7.1 Diagnose function menu