66
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
9. TECHNICAL
SPECIFICATIONS
Type
TARGET FEED MASTER RF
Main supply fuse F1
1A, fast-blow
Mains supply/frequency
115/230V+10% -20%, 20VA, 50/60Hz
14Vdc output
14 Vdc±10%, regulated,100mA max.
14Vdc output fuse F2
1A, fast-blow
Alarm Relay
10mA to 2A, 24 Vac or dc max.
Relay Output 1
5A, 250VAC max.
Housing
IP54, plastic casing
Operating temperature
0 to 40°C (32 to 104°F)
Storage temperature
-15 to 50°C (32 to 104°F)
Ambient relative humidity
max. 95%
Alarm Relay
10mA to 2A, 24 Vac or dc max.
Pollution degree
2
Altitude
Up to 2000m
Installation Category:
Class II
Type
PSFS-1
Input fuse F1
2.5A, slow-blow
Input
120VAC, +10%, -20%, 20VA, 50/60Hz
Output Voltage
±13-22VDC No load
Output Current
1A max, intermittent duty (10sec ON,
30 sec OFF)
Housing
IP54, plastic casing
Operating temperature
0 to 40°C
Storage temperature
-15 to 50°C
Ambient relative humidity
max. 95%
Type
TRB-8
Main supply fuse F2
1A, fast-blow
Mains supply/frequency
115/230V+10% -20%, 20VA, 50/60Hz
Relay Output 1-8:
10A Res, 1/2HP 250VAC
Housing
IP54, plastic casing
Operating temperature
0 to 40°C
Storage temperature
-15 to 50°C
Ambient relative humidity
max. 95%
The room temperature where the controller is located must
always remain between 32
o
and 104
o
F (0
o
and 40
o
C).
For indoor use only.
7
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
2
SYSTEM OVERVIEW
2.1
Description of the Controller
The
TARGET FEED MASTER RF controller is an electronic device
which takes in charge the feed weighing and distribution process
in 2 houses. The scale provided with the controller measures feed
with accuracy. Therefore, the user always knows the amount of
feed remaining in each bin.