28
TARGET FEED MASTER
TARGET FEED MASTER rev.09
5.3.5 Feed Consumption and Mortality History
The houses' history menu contains the feed consumption history and the
mortality history. These values are logged everyday for the past 45 days.
Use the arrow keys to select the de-
sired house from the main menu then
press the right-arrow key.
Press the down-arrow key to select
the "
4. History
" menu then press the
right-arrow key.
Select the desired history amongst the
following possibilities:
- Mortality History;
- Consumption History per bird or per
100 birds;
- Total consumption history
- Consumption correction history.
•
Press the down-arrow key to scroll the display and look at the selected
history.
These histories are cleared when a new flock starts.
4. House 1
4. History
4.4 House 1 History
1. Mortality
2. Cons. / 100
3. Tot. Cons.
37
TARGET FEED MASTER
TARGET FEED MASTER rev.09
Time clock outputs:
Set the proper number of time clock
outputs. Ranges from 0 to 8 time
clocks.
If the Timed Feeding distribution method
is enabled above, 1 time clock per house
is automatically activated.
Units:
Select the weight's units of measure-
ment: kilograms (kg) or pounds (lbs).
Feed Quantity (Consumption Mode):
The feed consumption can either be
displayed as an average weight per
bird or per 100 birds. Select the
desired displaying method: "
/bird
" or
"
/100
".
Time of reset:
Time at which the different values are stored in the histories and at
which the birds' age is increased by one day.
Shut off augers on a run time alarm?
This function allows stopping the auger motors when a run time alarm
occurs. This type of alarm usually happen when a bin is empty.
Use max feed?
This function allows limiting the daily amount of feed that is distributed
to the birds. When this option is enabled, feed stops being distributed
when the maximum feed limit is reached.
Max feed alarm?
This function allows setting off an alarm when the maximum allowable
amount of feed has been distributed.
9.1 Inst. Settings
# of bins: 6
# of houses: 2
# of blends: 8
Timed feeding: Yes
# time clocks: 8
Units: kg
Feed qty: /100
Time of reset: 0:00
Shutoff augers on
run time alarm? Yes
Use max feed? Yes
Max feed alarm? Yes