50
TARGET FEED MASTER rev.09
7. TROUBLESHOOTING GUIDE
PROBLEM
CAUSE
SOLUTION
- The fuse of the
PSFS-1 is blown
The valve
does not open
when the
PSFS-1 is
connected.
- Turn the power off and
replace the fuse with a 2.5A
slow blow fuse.
Make sure not
to bend the fuse holder !
- There is a problem
with the power supply.
- Check for 12VAC at
the 12VAC terminals
of the PSFS-1.
- The wiring is incorrect
- The transformer is defective
- Check for 12 to 20VDC on
the MOTOR terminals of the
PSFS-1.
- Remove all wires from the
DIR terminal of the PSFS-1: if
the valve opens, then the 2
motor wires are inverted.
Interchange the 2 wires going
to the motor.
- The PSFS-1 is
defective
- Replace the PSFS-1 module.
The main
controller
does not turn
on.
- Fuse F1 is blown.
- Replace the fuse.
- The wiring is incorrect. - Turn off the power.
- Remove all wires from the
MODULE terminals of the
main controller.
- Wait 5 minutes.
- Apply power to the main
controller : If the controller
starts then there is a wiring
problem.
- Fix the wiring.
15
TARGET FEED MASTER
TARGET FEED MASTER rev.09
Feed Weigher for
Breeders VX.X
9. Installation
9. Installation
3. Relay Assign.
9.3 Relay Assign.
1. Bin Augers
2. Output Augers
3. Time Clock Rlys
4. Mixing Relay
5. Scale 2 Valve
9.3.1 Bin Relays
Bin Auger 2
Mod: 3 Rly: 8
...
Module ID Assignment
ID#3 use relay 1-8
ID#4 use relay 1-16
ID#5 use relay 17-32
9.3 Relay Assign.
6. ID Assignment
9. Installation
4. Bin Setting
9.4 Bin Settings
1. Bin 1
2. Bin 2
9.4.1 Bin 1 Settings
Max fill time: 15
Re-order point: None
Alarm if empty: Yes
Backup bin: 3
9.Installation
5. Scale Calibr.
9.5 Scale Calibr.
1. Scale 1
2. Scale 2
Scale 1
Calib Weight: 10.0
Push + for next step
Scale is: Empty
Feed Weigher for
Breeders VX.X
10. Password
10. Password
Current mode
User
10. Password
Enter password
00 ** **
9.2 Scale settings
1. Scale 1
2. Scale 2
Scale 1
Actual Weight: 0.00
Max Batch: 20kg
With Valve? Yes
Blend size 50kg
Min Prox Sw.? Yes
Alarm on Max? Yes
Open On Alarm? No
Use Mixer: Yes
Mix Time: 1:00(m:s)
Delivery: 1:00(m:s)
Stability tol: 50
Mix Each batch: Yes
Dump Separately: Yes
9. Installation
2. Scale Settings