60
TARGET FEED MASTER rev.09
A
Age see Birds
Alarms
Acknowledging an alarm
34
Max feed alarm
37
Settings
37, 46
Troubleshooting guide
50
Animals see Birds
Augers
Bin augers see Bin
Output auger see Output Augers
Shutoff augers on alarm
37
Status
23
B
Backup
see Memory card
Bin
Activation
36
Adding feed to a bin
24
Backup bin
47
Bin auger
House selection see House
Location
10
Manual activation
23, 49
Relay assignment
44
Status
23
Remaining feed & other bin info
25
Settings
46
Birds
Bird age
23
Mortality
20, 28
Number
Posting initial # of bird
18
Posting mortalities
20
Remaining number
20
Starting a new flock
18
Blends
Activation
36
Blend curves
Principle of operation
31
Settings
32
Current distributed blend
23
Ingredient selection
30
Mixing the ingredients
39
Buttons
7
Shortcut keys
12
C
Calibration
48
Card
Memory card
58
Clock outputs see Time clock
Clock settings
29
Connections
8
Consumption see Feed consump.
Controller
Connections
8
Menus
13
Mounting instructions
8
Safety backup
see Memory card
Serial number
2
Curves see Blend curves
D
Date
29
Day
Setting the time and date
29
Distribution see Feed distrib.
E
Empty tolerance
40
Error (transfer)
59
Errors
Alarm
34
Troubleshooting guide
50
F
Feed bins see Bin
Feed blends see Blends
INDEX
5
TARGET FEED MASTER rev.09
1. INTRODUCTION
1.1 PRECAUTIONS, CARE & MAINTENANCE
WARNING: Read and save
these instructions!
Safety may be jeopardized if the equipment is used in a manner not specified by
the manufacturer. Carefully read and keep the following instructions for future
reference.
•
Although fuses at the input and outputs of the controller protect its circuits
in case of an overload or overvoltage, we recommend installing an addi-
tional protection device on the controller's supply circuit.
•
The room temperature where the controller is located must always remain
between 32 °F and 104 °F (0 °C to 40 °C). For Indoor use only !
•
To avoid exposing the controller to harmful gases or excessive humidity, it
is preferable to install it in a corridor.
•
Do not spray water on the controller! In order to clean the control, wipe it
with a damp cloth.
Before servicing or cleaning unit, switch power off at service panel and
lock the switch disconnecting means to prevent power from being
switched accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
•
The controller should be opened and inspected once a year for moisture.
Proper care will extend the life of the control.
IMPORTANT:
Use Grounded Metallic Conduits Only!
The conduit that brings feed into the scale must absolutely be
made of metal and must be grounded in order to prevent static
electricity. A high static electrical charge may cause malfunc-
tion to the controller.