8
TARGET FEED MASTER rev.09
3. INSTALLATION
3.1 MOUNTING INSTRUCTIONS
Remove the four screws in the front cover and lift the cover. Remove the
black caps located on the three mounting holes. Mount the enclosure to
the wall using three screws. Be sure the electrical knockouts are at the
bottom of the enclosure in order to prevent water from entering the
controller. Insert the screws into the mounting holes and tighten.
Fasten
the black caps onto the mounting holes.
3.2 CONNECTIONS
To connect the controller, refer to the wiring diagram enclosed with this
user's manual. Use the electrical knockouts provided at the bottom of the
enclosure. Do not make additional holes in the enclosure, particularly on
the side of the enclosure when using a computer communications module.
All wiring must be done by an authorized electrician and
must comply with applicable codes, laws and regula-
tions. Be sure power is off before doing any wiring to
avoid electrical shocks and equipment damage.
Do not install rigid conduit into electrical knockouts.
Only nylon cable glands are permitted for cable or wire
fastening.
The controller has no power-on switch. An external
switch or circuit breaker shall be included in the
building installation to interrupt power to L and N
electric power lines. It shall be in close proximity to the
equipment and within easy reach of the operator. It
shall be marked as the disconnecting device for the
equipment.
57
TARGET FEED MASTER rev.09
9. TECHNICAL SPECIFICATIONS
Type
TARGET FEED MASTER
Main supply fuse F1
1A, fast-blow
Mains supply/frequency
115/230V+10% -20%, 20VA, 50/60Hz
14Vdc output
14 Vdc ±10%, regulated, 100mA max.
14Vdc output fuse F2
1A, fast-blow
Relay Output 1
5A, 250VAC max.
Relay Outputs 2-3
230Vac, 1/2HP, 5A
Alarm Relay
10mA to 2A, 24 Vac or dc max.
Housing
IP54, plastic casing
Operating temperature
0 to 40°C (32 to 104°F)
Storage temperature
-15 to 50°C (32 to 104°F)
Ambient relative humidity
max. 95%
Pollution degree
2
Altitude
Up to 2000m
Installation Category:
Class II
Type
PSFS-1
Input fuse F1
2.5A, slow-blow
Input
120VAC, +10%, -20%, 20VA, 50/60Hz
Output Voltage
±13-22VDC No load
Output Current
1A max, intermittent duty (10sec ON,
30 sec OFF)
Housing
IP54, plastic casing
Operating temperature
0 to 40°C
Storage temperature
-15 to 50°C
Ambient relative humidity
max. 95%
Type
TRB-8
Main supply fuse F2
1A, fast-blow
Mains supply/frequency
115/230V+10% -20%, 20VA, 50/60Hz
Relay Output 1-8:
10A Res, 1/2HP 250VAC
Output fuses F1, F3, F4, F5,
F6, F7, F8, F10:
10A, slow blow
Housing
IP54, plastic casing
Operating temperature
0 to 40°C
Storage temperature
-15 to 50°C
Ambient relative humidity
max. 95%
The room temperature where the controller is located must always
remain between 32
o
and 104
o
F (0
o
and 40
o
C).
For indoor use only.