7.Mains connection
cabling
The mains cable provided is thermally resistant, complying to the most recent international
standards
NB:
In case of cable replacement, similar cable with comparable thermal resistant
qualities must be used exclusively (cable 3x1.5 ø external 8 mm, rated 300/500V,
tested to 2KV, operating temperature -40° +180°).
mains connection
ProSpot
can operate at voltages from 208V-230V-240V at 50 or 60Hz (operating
voltage and frequency can be selected as described in section 5 of this manual).
Prior to connecting the unit to your mains supply, ensure that the model in your pos-
session correctly matches the mains supply available to you.
For connection purposes, ensure your plug is of a suitable rating: 3 amps.
Locate the mains cable which exits the base of the unit and connect as shown
below:
protection
The use of a thermal magnetic circuit breaker is recommended for each
ProSpot.
A good earth connection is essential for the correct operation of the fixture. Strict
adherence to regulatory norms is strongly recommended.
marrone - brown
blu - blue
giallo/verde - yellow/green
marrone - brown
blu - blue
giallo/verde - yellow/green
massa
ground
neutro
neutral
fase
phase
alimentazione
main
marrone - brown
blu - blue
giallo/verde - yellow/green