background image

AV-452 Serial Control Specification

                                       7733 Telegraph Road   •   Montebello, CA 90640   •   (323) 726-0303   •   http://www.tascamcontractor.com
All features and specifications are subject to change without notice.  Contact your local TASCAM representative for the latest information.

Page 7 of 8

AV-452_RS-232_spec.pdf

031104

AMP A, AMP B, INTERCOM & CASCADE

The AMP A, AMP B INTERCOM and CASCADE buttons work 
just like the MUTE buttons for the channels.  These just 
have on and off states, and offer the same type of tally 
information.  The examples are given below for AMP A, just 
change the parameters numbers for AMP B "08" (30h 38h), 
INTERCOM "09" (30h 39h) or CASCADE IN "10" (31h 30h).

It should be noted that AMP A and AMP B buttons do not 
power the amplifiers on and off... these buttons are mute 

controls feeding the amps.  These amps do have a power 
switch in the rear separate from the main power, and there 
is no status information on that switch.  

Also, the CASCADE functionality changes with dip switch 
settings on the rear panel of the AV-452.  (One mode mixes 
the cascade input with the internal system, the other mode 
replaces the internal signal with the cascade port.)  See the 
AV-452 Owner's Manual for more detailed information.

AMP A OFF

7

37h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

N

4Eh

c

63h

A

41h

0

30h

CR

0Dh

0

30h

.

2Eh

AMP A ON

7

37h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

N

4Eh

c

63h

A

41h

0

30h

CR

0Dh

1

31h

.

2Eh

QUERY AMP A

7

37h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

N

4Eh

q

71h

A

41h

0

30h

CR

0Dh

0

30h

.

2Eh

STATUS - AMP A OFF (ID 1)

7

37h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

0

30h

s

73h

1

31h

0

30h

CR

0Dh

0

30h

.

2Eh

STATUS - AMP A ON (ID 1)

7

37h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

0

30h

s

73h

1

31h

0

30h

CR

0Dh

1

31h

.

2Eh

INTERCOM ON

9

39h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

N

4Eh

c

63h

A

41h

0

30h

CR

0Dh

1

31h

.

2Eh

QUERY INTERCOM

9

39h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

N

4Eh

q

71h

A

41h

0

30h

CR

0Dh

0

30h

.

2Eh

AMP B OFF

8

38h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

N

4Eh

c

63h

A

41h

0

30h

CR

0Dh

0

30h

.

2Eh

AMP B ON

8

38h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

N

4Eh

c

63h

A

41h

0

30h

CR

0Dh

1

31h

.

2Eh

QUERY AMP B

8

38h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

N

4Eh

q

71h

A

41h

0

30h

CR

0Dh

0

30h

.

2Eh

STATUS - AMP B OFF (ID 1)

8

38h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

0

30h

s

73h

1

31h

0

30h

CR

0Dh

0

30h

.

2Eh

STATUS - AMP B ON (ID 1)

8

38h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

0

30h

s

73h

1

31h

0

30h

CR

0Dh

1

31h

.

2Eh

INTERCOM OFF

9

39h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

N

4Eh

c

63h

A

41h

0

30h

CR

0Dh

0

30h

.

2Eh

STATUS - INTERCOM OFF (ID 1)

9

39h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

0

30h

s

73h

1

31h

0

30h

CR

0Dh

0

30h

.

2Eh

STATUS - INTERCOM ON (ID 1)

9

39h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

0

30h

0

30h

s

73h

1

31h

0

30h

CR

0Dh

1

31h

.

2Eh

CASCADE OFF

0

30h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

1

31h

N

4Eh

c

63h

A

41h

0

30h

CR

0Dh

0

30h

.

2Eh

CASCADE ON

0

30h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

1

31h

N

4Eh

c

63h

A

41h

0

30h

CR

0Dh

1

31h

.

2Eh

QUERY CASCADE

0

30h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

1

31h

N

4Eh

q

71h

A

41h

0

30h

CR

0Dh

0

30h

.

2Eh

STATUS - CASCADE OFF (ID 1)

0

30h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

1

31h

0

30h

s

73h

1

31h

0

30h

CR

0Dh

0

30h

.

2Eh

STATUS - CASCADE ON (ID 1)

0

30h

.

2Eh

LF

0Ah

.

2Eh

.

2Eh

1

31h

0

30h

s

73h

1

31h

0

30h

CR

0Dh

1

31h

.

2Eh

Summary of Contents for AV-452

Page 1: ...AV 452 machines to be connected to a single serial line and still be addressed individually If you are not using multiple machines this should probably be set to 1 The RS 422 and RS 485 operation fol...

Page 2: ...uery or return status string A lowercase c 63h indicates a command for the AV 452 q 71h indicates a query for the AV 452 to respond to and s 73h indicates a status return string from the AV 452 In the...

Page 3: ...OFF 2 32h 2Eh LF 0Ah 2Eh 2Eh 0 30h N 4Eh c 63h A 41h 0 30h CR 0Dh 0 30h 2Eh MUTE CHANNEL 3 ON 2 32h 2Eh LF 0Ah 2Eh 2Eh 0 30h N 4Eh c 63h A 41h 0 30h CR 0Dh 1 31h 2Eh QUERY MUTE 3 STATUS 2 32h 2Eh LF...

Page 4: ...This includes CASS CD RW DVD VCR and AUX shown at right These work like a home receiver one of these five buttons will be active at all times In the signal flow diagram this switch is in the bottom ce...

Page 5: ...N 4Eh q 71h A 41h 0 30h CR 0Dh 0 30h 2Eh STATUS CASSETTE ID 1 1 31h 2Eh LF 0Ah 2Eh 2Eh 1 31h 0 30h s 73h 1 31h 0 30h CR 0Dh 0 30h 2Eh STATUS CDRW ID 1 1 31h 2Eh LF 0Ah 2Eh 2Eh 1 31h 0 30h s 73h 1 31h...

Page 6: ...30h CR 0Dh 0 30h 2Eh REC MON CASSETTE 2 32h 2Eh LF 0Ah 2Eh 2Eh 1 31h N 4Eh c 63h A 41h 0 30h CR 0Dh 1 31h 2Eh REC MON CD RW 2 32h 2Eh LF 0Ah 2Eh 2Eh 1 31h N 4Eh c 63h A 41h 0 30h CR 0Dh 2 32h 2Eh QUER...

Page 7: ...h 2Eh 2Eh 0 30h N 4Eh q 71h A 41h 0 30h CR 0Dh 0 30h 2Eh STATUS AMP A OFF ID 1 7 37h 2Eh LF 0Ah 2Eh 2Eh 0 30h 0 30h s 73h 1 31h 0 30h CR 0Dh 0 30h 2Eh STATUS AMP A ON ID 1 7 37h 2Eh LF 0Ah 2Eh 2Eh 0 3...

Page 8: ...1 31h N 4Eh c 63h A 41h 0 30h CR 0Dh 0 30h 2Eh ROOM VOLUME UP 8 38h 2Eh LF 0Ah 2Eh 2Eh 1 31h N 4Eh c 63h A 41h 0 30h CR 0Dh 1 31h 2Eh QUERY ALL STATUS This command triggers the AV 452 to send all sta...

Reviews: