TASCAM CD-A750 RS-232C Protocol Specifications
17
TEAC
Corporation
0 2
–36dB
0 3
–42dB
0 4
–48dB
Request/Preset AUTO CUE LEVEL PRESET [20]
AUTO CUE SELECT RETURN
This is the return command in response to the command "AUTO CUE SELECT [30]".
It returns the Auto Cue on/off status.
Command B0
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
0
0
Auto Cue Off
0
1
Auto Cue On
Request/Preset AUTO CUE SELECT [30]
EOM TRACK TIME RETURN
This is the return command in response to the command "EOM TRACK TIME PRESET [32]".
It returns the time at which the EOM (End Of Message) function will give notice that the end of the
track is near.
Command B2
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
0
0
EOM Track Off
N1
N2
Number of seconds
N1: Tens digit of seconds, N2: Ones digit of seconds
Request/Preset EOM TRACK TIME PRESET [32]
TIMER/RESUME PLAY SELECT RETURN
This is the return command in response to the command "TIMER/RESUME PLAY SELECT [34]".
It returns the status of the Timer play setting and Resume play mode.
Command B4
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
0
0
Timer Play: Off / Resume Play: Off
0
1
Timer Play: On / Resume Play: Off
0
2
Timer Play: Off / Resume Play: On
0
3
Timer Play: On / Resume Play: On
Request/Preset TIMER/RESUME PLAY SELECT [34]
PITCH CONTROL SELECT RETURN
This is the return command for the command "PITCH CONTROL SELECT [35]".
It returns the Pitch Control on/off status.
Command B5
Machine ID
0
Data 2
bytes
Data 1
Data 2
Description
Remarks
0 0
Pitch
Control
Off
0 1
Pitch
Control
On
Request/Preset PITCH CONTROL SELECT [35]