TASCAM CD-A750 RS-232C Protocol Specifications
23
TEAC
Corporation
REC MUTE
Executes the REC MUTE on cassette deck of the controlled device.
Command 1B
Machine ID
1
Data none
Return none
PAUSE
Puts the cassette deck of the controlled device in PAUSE mode.
Command 1C
Machine ID
1
Data none
Return none
RTZ
Executes the RTZ on cassette deck of the controlled device.
Command 1D
Machine ID
1
Data none
Return none
MECHA STATUS SENSE
Requests that the current mechanism status of the cassette deck of the controlled device be
returned.
Command 50
Machine ID
1
Data none
Return
MECHA STATUS RETURN [D0]
MEDIA STATUS SENSE
Requests that the presence or absence of a media and the type of media be returned.
Command 56
Machine ID
1
Data none
Return
MEDIA STATUS RETURN [D6]
COUNTER SENSE
Requests that the counter information of the cassette deck of the controlled device be returned.
Command 5A
Machine ID
1
Data none
Return
COUNTER RETURN [D6]
COUNTER RESET
Resets the counter of the cassette deck of the controlled device.
Command 65
Machine ID
1
Data none
Return none
MECHA STATUS RETURN
This is the return command for the command "MECHA STATUS SENSE [50]".
It returns the current operating status of the mechanism.
Command D0