TASCAM CD-A750 RS-232C Protocol Specifications
24
TEAC
Corporation
Machine ID
1
Data 4
bytes
Data 1
Data 2
Description
Remarks
1 0
Stop
1 1
Play
1 3
Record
1 4
Record-Pause
1 A
F.FWD/REW
1 C
Pause
Data 3
Data 4
Description
Remarks
0 0
No
direction
0 1
Forward
direction
0 2
Reverse
direction
Request/Preset MECHA STATUS SENSE [50]
MEDIA STATUS RETURN
This is the return command for the command "MEDIA STATUS SENSE [56]".
It returns the presence/absence of a media, and the type of media.
Command D6
Machine ID
1
Data 4
bytes
Data 1
Data 2
Media Status
00: Media not present
01: Media present
Data 3
Data 4
Write Protect tabs
00: Forward = permitted / Reverse = permitted
01: Forward = prohibited / Reverse = permitted
10: Forward = permitted / Reverse = prohibited
11: Forward = prohibited / Reverse = prohibited
Request/Preset MEDIA STATUS SENSE [56]
COUNTER RETURN
This is the return command for the command "COUNTER SENSE [5A]".
It returns the current counter data.
Command DA
Machine ID
1
Data 4
bytes
Description
Remarks
Data 1
Thousands digit of counter data
Data 2
Hundreds digit of counter data
Data 3
Tens digit of counter data
Data 4
Ones digit of counter data
Request/Preset COUNTER SENSE [5A]
Common functions
INFORMATION REQUEST
Requests the controlled device to return information such as the software version.
Command 0F
Machine ID
0 or 1
Data none
Return INFORMATION
RETURN
[8F]