TASCAM CD-A750 RS-232C Protocol Specifications
25
TEAC
Corporation
REMOTE/LOCAL SELECT
Enables or disables key operations on the controlled device's own panel.
A return command is returned only if Sense [FF] is specified.
Command 4C
Machine ID
0 or 1
Data 2
bytes
Data 1
Data 2
Description
Remarks
0 0
Remote Only
remote
operation via RS-232C will be enabled. Key
operations on the device's own panel and remote controller
will be disabled.
0
1
Local
Remote operation and key operations on the device's own
panel will be enabled.
F F
Sense Requests
that
the
preset content be returned.
・
If data other than the above is received, the controlled device will transmit ILLEGAL [F2].
Return
REMOTE/LOCAL SELECT RETURN [CC]
ERROR SENSE
Requests that error data be returned from the controlled device.
If the controlled device issues an "ERROR SENSE REQUEST [F0]," you should use this command to
check the content of the error.
Command 78
Machine ID
0 or 1
Data none
Return
ERROR SENSE RETURN [F8]
INFORMATION RETURN
This is the return command in response to the command "INFORMATION REQUEST [0F]."
It returns the software version of the controlled device.
Command 8F
Machine ID
0
Data 4
bytes
Data 1
Tens digit of the software version
Example of Data 1 – Data 4
Data 2
Ones digit of the software version
0100
Version 1.00
Data 3
First decimal place of the software
version
Data 4
Second decimal place of the software
version
Request
INFORMATION REQUEST [0F]
REMOTE/LOCAL SELECT RETURN
This is the return command for the command "REMOTE/LOCAL SELECT [4C]."
It returns the enabled or disabled status for operation of the device's panel keys.
Command CC
Machine ID
0 or 1
Data 2
bytes
Data 1
Data 2
Description
Remarks
0
0
Remote
Only remote operations via RS-232C will be enabled. Key
operations on the device's own panel and remote controller
will be disabled.
0
1
Local
Remote operations as well as operations of the device's own
panel will be enabled.
Request/Preset REMOTE/LOCAL SELECT [4C]