SRC
This turns the sample rate converter on/off for each signal line
Options:
OFF
(default value),
ON
NOTE
i
SRC
cannot be set to
ON
for the signal line selected as the
master clock. In this case, the following pop-up window ap-
pears.A confirmation pop-up message appears.
i
If an IF-AE16 is installed, depending on the main unit
SRC
item setting and clock master setting, an error described as
“SRC for the IF-AE16 signal line selected as the CLOCK MASTER
is ON” could occur.
In this case, the
SRC
item for that signal line will be turned
off automatically and the INFO indicator will light red. In this
situation, press the INFO button to open the following alert
message. Once this has been confirmed, it will disappear.
i
The INFO indicator lights red when an error has occurred with
the IF-AE16 input signal. In this situation, press the INFO but-
ton to show the following information. Note that even if there
is an error with the input signal, it will not mute.
Unlocked: The input signal is not synchronized with the main
unit.
no signal: There is no input signal.
not audio: The input signal Cbit data is “not audio”.
Dual Line: The input signal Cbit data is “Dual Line”.
Function added to synchronize with SMPTE timecode and play the current take
A function has been added to play the current take synchronized
with the SMPTE timecode input through the TIMECODE IN con-
nector on the back of the unit.
A
TC SYNC
page has been added to the menu for this function.
Setting timecode synchronized playback
Use the
TC SYNC
page to make timecode synchronized play-
back settings.
TC CHASE MODE
Turn timecode synchronized operation on/off.
Options:
OFF
(default value),
ON
NOTE
You can also press the
9
[CHASE] button while pressing and
holding the SHIFT button on the front of the unit to turn it
on/off.
TC CHASE OFFSET
A timecode offset can be set for the input timecode.
The setting range is from
-23:59:59.29
to
+23:59:59.29
.
Function (default value)
TC RECHASE MODE
This turns on/off the resynchronization function for when syn-
chronization becomes inaccurate during timecode synchro-
nized playback.
Options:
OFF
(default value),
ON
When set to
OFF
, after being synchronized once the input
timecode is ignored and the unit operates in free run mode.
When set to
ON
, rechasing will start when the synchronization
inaccuracy exceeds the threshold level set on the
TC RE-
CHASE THRESH
screen.