DA-6400/DA-6400dp
26
TASCAM DA-6400/DA-6400dp
New functions in firmware version 1.40
The following new functions have been added in firmware version 1.40.
0
The TASCAM IF-AN16/OUT analog output interface card is now supported.
TASCAM IF-AN16/OUT analog output interface card support added
The TASCAM IF-AN16/OUT analog output interface card is now
supported.
If installed in SLOT 1 or SLOT 2 of this unit, the following appears
on the
SLOT1
or
SLOT2
menu page.
NOTE
i
The IF-AN16/OUT cannot be set as this unit's master clock. If
you try to set it, the following pop-up message will appear.
i
If an IF-AN16/OUT is installed, replacing a slot card, or
SYS-
TEM BACKUP
settings are imported, the IF-AN16/OUT could
become set improperly as the master clock.
If this occurs, the master clock setting will automatically be
switched to
Internal
and the INFO indicator will light red.
In this state, the following message will appear if you open the
INFORMATION
screen. After confirming this message once, it
will not appear again.
i
If an input signal is assigned for the slot in which the IF-AN16/
OUT is installed and the
PREFERENCES
page
NO SIGNAL
ERROR CHECK
item is set to
ON
, the INFO indicator will light
red and a message like “
SLOT 1 has no signal
” will ap-
pear on an
ERROR INFORMATION
screen.
If you do not want such error messages to appear, set the
PREFERENCES
page
NO SIGNAL ERROR CHECK
item to
OFF
.
Adjusting output levels
You can adjust the output levels of the IF-AN16/OUT to suit the
connected devices. All 16 channels can be adjusted individually
or together.
1.
Select the
SLOT 1
or
SLOT 2
menu page
OUTPUT AT-
TENUATOR
item, and press the MULTI JOG dial to open the
OUTPUT ATTENUATOR
settings list for that slot.
[SLOT 2 page]
[OUTPUT ATTENUATOR setting list]
2.
Turn the MULTI JOG dial to select the channel you want to
adjust, and press the MULTI JOG dial to open the OUTPUT
ATTENUATOR setting adjustment screen.
[OUTPUT ATTENUATOR setting adjustment screen]
3.
Select the
EDIT MODE
item, and turn the MULTI JOG dial to
set how the values are changed.
Press the MULTI JOG dial to move the cursor to the next item.
You can also use the . and / buttons to move the cursor.
Option
Meaning
Individual
(default value)
Change settings for 1 channel at a
time.
ALL
Change settings for all 16 channels
at the same time.
BATCH SETUP
Change settings for multiple desig-
nated channels at the same time.