background image

 

 

                                                                                                      TASCAM DV-RA1000 RS-232C

プロトコル仕様書

 

                                                                                                                                                                                               
 19 

ティアック株式会社

 

5-8. REPEAT SELECT RETURN 

Transmitted in response to a REPEAT SELECT command [37] with the request data ([FF]) to show the 
currently set the repeat function status. 

Command B7 
Data 2 

bytes 

Request command  REPEAT SELECT [37]   
 

Data 1 

Data 2

Description 

Remarks 

Repeat Off 

Repeat mode is off 

All Repeat   

All Repeat mode is on 

Single Repeat 

Single Repeat mode is on 

A-   

Start point of A-B repeat is set 

A-B Repeat   

A-B Repeat mode is on 

 

5-9. AUTO SPACE SELECT RETURN 

Transmitted in response to an AUTO SPACE SELECT command [3B] with the request data ([FF]) to 
show the currently set the Auto Space mode status. 

Command BB 
Data 2 

bytes 

Request command  AUTO SPACE SELECT [3B] 
 

Data 1 

Data 2

Description 

Remarks 

Auto Space Off

Auto Space function is off 

Auto Space On

Auto Space function is on 

 

5-10. MUTE SENSE RETURN 

Transmitted in response to an MUTE SELECT command [3C] with the request data ([FF]) to show the 
currently set the Mute mode status. 

Command BC 
Data 2 

bytes 

Request command  MUTE SELECT [3C] 
 

Data 1 

Data 2

Description 

Remarks 

Mute Off 

Mute function is off 

Mute On 

Mute function is on 

 

5-11. FADE IN/OUT SELECT RETURN 

Transmitted in response to a FADE IN/OUT SELECT command [3E] with the request data ([FF]) to show 
the currently set the Fade In/Out function status. 

Command BE 
Data 2 

bytes 

Request command  FADE IN/OUT SELECT [3E] 
 

Data 1 

Data 2

Description 

Remarks 

Fade In/Out Off 

 

Fade In/Out Rehearsal 

 

Fade In/Out On 

 

 

Summary of Contents for DV-RA1000HD

Page 1: ...TASCAM DV RA1000HD CONTROL I O Terminals RS 232C Protocol Specifications Ver 1 00 October 2007 TEAC...

Page 2: ...voltage is between 5 V and 15 V against a load impedance of between 3 kohm and 7 kohm Signal discrimination Logical 1 3V Logical 0 3V Communication format Circuit type 3 wire Half duplex Transmission...

Page 3: ...TASCAM DV RA1000HD RS 232C Protocol Specifications 2 TEAC Corporation 2 3 5 RXD TXD RTS CTS GND RXD TXD RTS CTS GND 7 8 DV RA1000HD External controller...

Page 4: ...achine ID 0 When the controlled device is in STOP READY mode this command starts playback The PLAY command is 12 and it is transmitted using the following sequence ID Command ASCII LF 0 1 2 CR HEX 0Ah...

Page 5: ...E SELECT RETURN 3C MUTE SELECT BC MUTE SELECT RETURN 3E FADE IN OUT SELECT BE FADE IN OUT SELECT RETURN 4D SINGLE PLAY SELECT 4E SINGLE PLAY SENSE CE SINGLE PLAY SENSE RETURN 50 MECHA STATUS SENSE D0...

Page 6: ...the CHANGE STATUS return command Command External controller Controlled device Status of the controlled device STOP PLAY Starts playback CHANGED STATUS Send the CHANGE STATUS return command Sample 2 T...

Page 7: ...he current machine status by using the MECHA STATUS SENSE command This example describes that checks the Record Ready status then starts recording Command External controller Controlled device Status...

Page 8: ...olled device into PLAY mode Command 12 Data None Return None 4 4 RECORD Puts the controlled device into RECORD READY mode When the controlled device is recording increments the track Adds the track ma...

Page 9: ...command is received playing or pausing is maintained after skipping Command 1A Data 2 bytes Return None Data 1 Data 2 Description Remarks 0 0 Track Skip Next Skips to the next track 0 1 Track Skip Pr...

Page 10: ...pitch control value Sample 2010 2 0 F F Pitch Control value request Requests the currently set the Pitch Control value If the specified data is out of range the controlled device sends ILLEGAL F2 4 1...

Page 11: ...a 10 Units digit of seconds Data 11 Tens digit of frames Data 12 Units digit of frames Sample 020003001030 2tr 03m 10s 30f Frame search can be done for DVD HDD only If the specified data Track number...

Page 12: ...s set using the PITCH CONTROL DATA PRESET command 25 Command 35 Data 2 bytes Return PITCH CONTROL SELECT RETURN B5 Data 1 Data 2 Description Remarks 0 0 Pitch Control Off Turns the Pitch Control mode...

Page 13: ...evice returns the AUTO SPACE SELECT RETURN command B6 Command 3B Data 2 bytes Return AUTO SPACE SELECT RETURN BB Data 1 Data 2 Description Remarks 0 0 Auto Space Off Turns the Auto Space function off...

Page 14: ...Data 1 Data 2 Description Remarks 0 0 Single Off 0 1 Single On If the specified data is other than described above the controlled device sends ILLEGAL F2 4 22 SINGLE PLAY SENSE Requests the status of...

Page 15: ...8 TITLE SENSE Requests the track or project title in the DVD HDD mode Requests the disc or track title in the CD mode Command 59 Data 4 bytes Return TITLE RETURN D9 Description Remarks Data 1 Tens dig...

Page 16: ...y are described in the CAUTION SENSE RETURN F9 command Command 79 Data None Return CAUTION SENSE RETURN F8 4 34 VENDER COMMAND This is an exclusive command for the DV RA1000HD Command 7F Data Not fixe...

Page 17: ...TASCAM DV RA1000 RS 232C 16 DRIVE SELECT Select the drive Data 4 bytes Data 3 Data 4 Description Remarks 0 0 ODD 0 1 HDD F F Sense Requests the current setting...

Page 18: ...ET command 25 with the request data FF to show the currently set Pitch Control value Command A5 Data 4 bytes Request command PITCH CONTROL DATA PRESET 25 Data 1 Data 2 Data 3 Data 4 Description Remark...

Page 19: ...B4 Data 4 bytes Request command RESUME PLAY SELECT 34 Data 1 Data 2 Description Remarks 0 2 Resume Off 0 3 Resume On 5 6 PITCH CONTROL SELECT RETURN Transmitted in response to a PITCH CONTROL SELECT...

Page 20: ...atus Command BB Data 2 bytes Request command AUTO SPACE SELECT 3B Data 1 Data 2 Description Remarks 0 0 Auto Space Off Auto Space function is off 0 1 Auto Space On Auto Space function is on 5 10 MUTE...

Page 21: ...mode Data 2 Drive 01 HDD HDD mode 00 No Disc A disc is not loaded 01 Eject Tray When LCD shows OPEN 02 CLOSE When LCD shows CLOSE or DISC READING Data 3 10 Stop Ready On Transport is in Stop or Ready...

Page 22: ...D Data R including blank disc 56 DVD Data RW including blank disc 58 DVD Data RAM including blank disc FF Unknown 5 16 CURRENT TRACK INFORMATION RETURN Transmitted in response to a CURRENT TRACK INFOR...

Page 23: ...of minutes Data 7 Tens digit of seconds Data 8 Units digit of seconds Data 9 Tens digit of frames DVD HDD mode only 0 at CD mode Data 10 Units digit of frames DVD HDD mode only 0 at CD mode 5 18 CURRE...

Page 24: ...Units digit of frames DVD HDD mode only 0 at CD mode If Data 1 to Data 4 is 0000 the inserted DVD disc is blank disc or no disc 5 20 PGM TOTAL TRACK No TOTAL TIME RETURN Transmitted in response to a...

Page 25: ...CAUTION SENSE request 79 in order to determine the error type Command F1 Data None Request command None 5 24 ILLEGAL STATUS Transmitted from the controlled device to the external controller in order...

Page 26: ...no signal 1 07 DIN speed illegal 1 08 Disc Full 1 09 Disc remain is not enough 1 10 Over 99 files 1 11 Over 2GB file 1 12 Unsupported medium 1 13 Delete Minimum size file 1 14 Divide cannot execute 2...

Page 27: ...MAND RETURN Transmitted in response to a VENDER COMMAND 7F giving some information of the DV RA1000HD Command FF Data 4 bytes Return VENDER COMMAND 7F Data 1 Data 2 Description Remarks 0 0 Monitor Sel...

Reviews: