TASCAM DV-RA1000 RS-232C
プロトコル仕様書
7
ティアック株式会社
4. Command Detail
Commands, data, and machine IDs which are described here are represented in characters (ASCII).
A command is a 2-byte character, a Machine ID is a 1-byte character, and each data is a 1-byte
character.
The DV-RA1000HD can have up to 99 tracks and up to 99 projects.
4-1. INFORMATION REQUEST
Requests the internal software version number of the controlled device.
Command 0F
Data None
Return
INFORMATION RETURN [8F]
4-2. STOP
Puts the controlled device into STOP mode.
Command 10
Data None
Return None
4-3. PLAY
Puts the controlled device into PLAY mode.
Command 12
Data None
Return None
4-4. RECORD
Puts the controlled device into RECORD READY mode. When the controlled device is recording,
increments the track. Adds the track mark.
Command 13
Data 2
bytes
Return None
Data 1
Data 2
Description
Remarks
0
1
Record Ready
Puts the controlled device into RECORD READY mode.
When the controlled device is recording, increments the track.
0
2
Track Mark
Adds the track mark.
・
If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
4-5. READY
Puts the controlled device into READY mode.
Command 14
Data 2
bytes
Return None
Data 1
Data 2
Description
Remarks
0 1
Ready
On
・
If the specified data is other than described above, the controlled device sends ILLEGAL [F2].