MMR-8
Tascam MMR-8 Owner’s Manual • Chapter 4 • MMR-8 Setup Menus
69
Setup Menu Chart
This chart lists all of the Setup Menus and their parameters. Note that * indicates the default selection.
MENU #
MENU NAME
PARAMETERS
000
Control Mode
Local/MMR*
Time Code Chase
Biphase Chase
Biphase Transport
Serial Transport
Editor
Varispeed
001
Frame Reference
Automatic*
Video
002
Sample Reference
Automatic*
AES/EBU Input
Ext Wordclock
003
Time Code Type
24/24
25/25
29.97/DF
29.97/NDF
30/DF
30/NDF*
004
Sample Rate
42294 (44x23/25)
42336 (44x24/25)
44056 (44100-)
44100
44144 (44100+)
45938 (44x25/24)
45983 (44x25/23)
46034 (48x23/25)
46080 (48x24/25)
47952 (48000-)
48000*
48048 (48000+)
50000 (48x25/24)
50050 (48x25/23)
100
Sync Group
1*
2
3
4
110
MMR Bus Request
Master
Off*
Slave