background image

 

Page 1 of 9 

TASER® CAM™ HD Battery 

Replacement Guide 

 

 

Summary of Contents for TASER CAM

Page 1: ...Page 1 of 9 TASER CAM HD Battery Replacement Guide ...

Page 2: ...ure to do so may result in power failure or charge failure due to the poor connection between the battery and the electronic circuitry of the device The instructions apply only to the TASER CAM HD recorder DO NOT attempt to change the battery in a previous generation TASER CAM device DO NOT attempt to replace the TASER CAM HD battery unless you have been trained in this procedure Contact TASER Int...

Page 3: ...amage to your battery pack do not allow a metal object to touch the battery contacts Do not strike or throw the battery against hard surfaces Do not directly solder the battery or pierce the battery with a nail or other sharp object Never disassemble short circuit or heat batteries or put batteries in a fire Doing so may cause battery explosion battery leakage system damage injury or fire Abnormal...

Page 4: ...Page 4 of 9 Parts Required The TASER CAM HD replacement battery kit includes 1 lithium ion battery 2 replacement screws You also will need a Torx T5 x 60 screwdriver not included but pictured below ...

Page 5: ...tery 1 Use the Torx screwdriver to remove the two screws in the top of the unit Using any tool not specifically designed for Torx fasteners may damage the screws and or the TASER CAM HD recorder 2 Carefully remove the plastic cover ...

Page 6: ...Page 6 of 9 3 Unplug the old battery Be careful not to pull on the wires only pull on the connector 4 With the battery disconnected remove the old battery from the unit ...

Page 7: ...place make sure to insert the battery in the same orientation the wires on the battery should be on the side closest to the camera lens 7 Reconnect the connector on the new battery Ensure the battery connection is fully seated in the connector and positioned flat with the bottom of the board If the connector is oriented correctly the red wire will be on top 8 Be careful not to pinch the wires or t...

Page 8: ...t damaged or forced out of alignment during the re assembly process Inspect to ensure the top is level with the top of the rest of the camera assembly and not bulging on either end or the middle 11 Use the replacement screws to secure the top in place Be careful not to over tighten the screws as this may strip out the plastic Always use the replacement screws and dispose of the original screws ...

Page 9: ...s a trademark of Acumen Global Technologies TASER CAM is a trademark of TASER International Inc and TASER and are registered trademarks of TASER International Inc registered in the U S All rights reserved 2014 TASER International Inc ...