5.7 HOSE CONNECTION

Make the hose connection(s) to the portable base and extend the hose(s) straight back from the portable base at least 10 feet (3
meters). If only one inlet of a double inlet base be used, a clapper valve will automatically close off the other inlet. Use caution when
turning on the water to the monitor on the portable base. As the hose fills it will become stiff and may cause the monitor and portable
base to slide or tip or both. Open the pumper valve to the monitor slowly.

5.8 PORTABLE BASE STORAGE

The portable base may be stored in a compartment, on the optional storage
bracket, TFT part number XF-B. This bracket is NOT designed to withstand the
reaction forces of an operating monitor stream. It is to be used for storage and
transportation only. The storage bracket may be mounted on a horizontal surface,
horizontally or vertically on a vertical surface, or on the underside of a horizontal
surface such as the top of a compartment. A strap helps hold the base on the
bracket. Mounting instructions are supplied with the bracket.

5.9 PRESSURE RELIEF OPTION

XF-B

STORAGE
BRACKET

XF-B

STORAGE
BRACKET

1

2

3

The optional pressure relief valve on the single inlet portable base can be adjusted
to open between 50 and 200 psi. The pressure relief valve, TFT part A1820, is set at
the factory to open at 150 psi. To change the relief pressure refer to the label on the
bottom side of the pressure relief valve. A pressure relief valve can be added to the
single inlet portable base by removing the cover on the side of the base. For
additional information call 800-348-2686.

6.0 MAINTENANCE

The CROSSFIRE® monitor and its base require little maintenance. The unit should be kept clean and free of dirt by flushing with water
after each use. All controls should be checked for freedom of movement and condition. Any inoperable or damaged part should be
repaired or replaced immediately. Specific areas to check are as follows:

Truck Mount Base:

1) Sealing surface above swivel joint must be smooth.
2) Swivel joint must rotate freely.

Portable Base:

1) Sealing surface above swivel joint must be smooth.
2) Swivel joint must rotate freely.
3) Legs and leg lock pins must move freely and lock in position.
4) Leg spikes must be sharp.
(replace if flats at tip of spikes exceed 1/16" diameter)

1

2

3

4

Monitor:

1) Handwheel must rotate freely.
2) Elevation stop pin must return to safe position.
3) Quick disconnect latch and safety catch must operate freely.
4) Rotation lock must operate freely and keep monitor from rotating
when engaged.

5.10 PRESSURE RELIEF VALVE SETTING

To set the relief valve pressure turn the adjusting screw on the relief valve housing
until the surface of the screw is even with the desired pressure. Do not cap or plug
discharge opening.

Adjusting
Screw

Relief Valve

Discharge

Opening

4

1

3

2

3

2

1

TFTX

-

XXXXXX

SERIAL

#:

SERIAL

#:

MODEL

#:

XFT

-NJ

MODEL

#:

XFT

-NJ

0

psi

200

120

12

80

60

40

20

10

4

0

2

bar

14

6

8

100

160

180

140

Summary of Contents for CROSSFIRE

Page 1: ...ing and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times 2 It is your responsibility to read and understand...

Page 2: ...with a particular hazard Per ANSI standard Z535 4 1998 the definitions of the three signal words are as follows DANGER CAUTION WARNING DANGER indicates an imminently hazardous situation which if not...

Page 3: ...the line or equipment Distance from the nozzle to the line or equipment Size of the stream Whether the stream is solid or broken Purity of the water 2 WARNING 1 2 Electrostatic Hazards of Foam Blanket...

Page 4: ...ontrols Figure 3 1 3 Figure 3 1 2 Figure 3 1 1 CROSSFIRE MONITOR TOP STOW A WAY 800 BASE TRUCK MOUNT ADAPTOR COMPANION FLANGE Carrying Handle Inlet Pressure Gauge Elevation Pin Stop Anchor Strap Stora...

Page 5: ...its down position as shown in Figures 4 4 1 4 4 2 Before the monitor is removed from the base the rotation lock should be manually disengaged A small spring holds the rotational lock in the unlocked p...

Page 6: ...n a portable base below this safety stop is DANGEROUS Do not operate on portable base below safety stop Injury or death can occur if the monitor and base slides or lifts off the ground Figure 4 4 1 Un...

Page 7: ...ation instructions are shipped with this accessory The storage bracket TFT part XF B for the base unit IS NOT STRONG ENOUGH to withstand the forces encountered with an operating monitor and is not int...

Page 8: ...hould be a safe distance from the fire yet within reach of the nozzle stream Select a flat even surface within 8 feet of a sturdy stationary object that can be used as an attachment point for the anch...

Page 9: ...strap in the base and protect the sealing surface of the quick connect swivel joint Whenever the monitor is operated on the portable base the base must be anchored to a substantial immovable object A...

Page 10: ...to the label on the bottom side of the pressure relief valve A pressure relief valve can be added to the single inlet portable base by removing the cover on the side of the base For additional inform...

Page 11: ...gear housing until excess appears 6 2 PERFORMANCE TESTS 7 0 SPECIFICATIONS CROSSFIRE Monitor STOW A WAY 800 Base Weight Storage Volume L W H Height Above Truck Flange Height Above Truck Deck min Heig...

Page 12: ...AINTENANCE Read instruction manual before use Operation of this device without understanding the manual and receiving proper training is a misuse of this equipment A person who has not read and unders...

Page 13: ...2 33 34 44 45 46 47 48 49 50 51 52 SWIVEL RING 1 X425 5 16 SS BALLS 76 VB 312 SWIVEL SCREW 2 X405 SHOT PIN KNOB 2 X430 KNOB BARREL 2 X440 SHOT PIN SPRING 2 X445 5 32 x 7 8 SPIROL PIN 2 V1900 SHOT PIN...

Page 14: ...Z LOCK 9991067 MIDSTATE 210049 1 A4230 27 COUPLING HEAD STROZ 5 X 5 25 PSF HARDCOAT 1 A4135 31 GASKET 5 PRESSURE MOLDED 9991000 1 A4220 32 BALL 7 16 STAINLESS 302 GRADE 100 1 VB 437 33 MATE PSM4 25 X...

Page 15: ...ended beneficiary of the equipment shall not be entitled to recover from TFT any consequential or incidental damages for injury to person and or property resulting from any defective equipment manufac...

Page 16: ...y tied down with no slack in anchor strap Flow Limited to 800 gpm 3000 l min Master nozzle pumped to 800 gpm or Stacked Tips Limited to PORTABLE BASE GENERAL WARNING 1 3 8 dia 175 PSI 1 1 2 dia 140 PS...