5.0 OPERATION

DECON/pak

PATENTED

UL502-D

PORTABLE DECONTAMINATION SYSTEM

TM

Valparaiso, IN 46383-9327

+1 219 462-6161 • 800 348-2

686 • MADE IN U.S.A.

www.tft.com

TASK FORCE TIPS

UL521

Read manual before use.

WARNING

Pat# 5,810,089

PUSH & TURN
TO ATTACH

CONTROL

FLOW

FILL

2.5 GAL

CONNECT

SUPPLY

ADJUST %

START UP PROCEDURE 

To Make Agent - Connect water supply. Attach the nozzle to the
Quick-Connect. Turn the Percentage Knob to the desired percentage.
Twist the Valve Handle to start water flow. 

5.1 HOSE CONNECTION

Attach inlet fire hose to the coupling on the inlet end of the DECON/pak. Larger hoses may be used with an adapter. For maximum 

maneuverability, we recommend attaching 1” hose into the DECON/pak itself.

5.2 FILLING TANK

Unscrew the fill port lid by turning counterclockwise. Fill tank to bottom of fill port. Agent may seep out the vents if over filled. Close 

the fill port lid by turning clockwise.

5.3 CONNECT DISCHARGE HOSE AND NOZZLE

1. The nozzle may be attached directly to the quick-connect fitting on the control block or to the end of the outlet hose which is then 

attached to the control block. Align the marks on the quick-connect male fitting with the marks on the female fitting and push the 

two pieces together. Twist the nozzle or hose one quarter turn to the right to latch the quick-connect fitting. 

2. To remove fan nozzle, remove set screw.

3. Hose lengths available. TFT part U-HS6, U-HS, and U-HS25.

CAUTION

The DECON/pak’s eductor will not work if the backpressure from the outlet hose or nozzle is too 

high. The 25’ (7.5m) U-HS25 optional hose is the maximum length that will work with the DECON/

pak. Adding additional hose, or using other hose assemblies and nozzles, may cause the DECON/

pak to not function properly.

CAUTION

There is no check valve in the DECON/pak eductor system. Do not install a shut off valve between 

the DECON/pak and the fan nozzle. This can cause the agent tank to fill with water and dilute the 

agent concentrate.

5.4 SETTING AGENT CONCENTRATION

Turn the knob to the desired concentrate percentage.  The percentage knob may be turned to the RINSE position for water only use. 

Be sure to use the agent manufacturer’s recommended concentrate ratio.

5.5 CONTROLLING FLOW

Pressurize the hose line. Turn the flow control valve to start water flowing through the DECON/pak. Flow may be reduced by partially 

closing the control valve.

Summary of Contents for DECON/pak

Page 1: ...gent can result in injury or damage to the environment Follow the agent concentrate manufacturer s instructions and fire service training to avoid using the wrong type of agent for decontamination purposes WARNING There is a wide variety of agent concentrates Each user is responsible for verifying that any agent concentrate chosen to be used with this unit has been tested to assure that the agent ...

Page 2: ...nt you may be called upon to use 3 It is your responsibility to know that you have been properly trained in Firefighting and or Emergency Response and in the use precautions and care of any equipment you may be called upon to use 4 It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use 5 ...

Page 3: ...T HAND OPERATION 4 0 AGENT SELECTION 4 1 AGENT COMPATIBILITY 5 0 OPERATION 5 1 HOSE CONNECTION 5 2 FILLING TANK 5 3 CONNECT DISCHARGE HOSE AND NOZZLE 5 4 SETTING AGENT CONCENTRATION 5 5 CONTROLLING FLOW 5 6 AGENT QUALITY 5 7 SHUT DOWN AFTER USE FLUSHING 5 8 STORAGE 6 0 TROUBLE SHOOTING 7 0 CLEAN UP AND MAINTENANCE 7 1 DRAIN HOLE 8 0 SPECIFICATIONS 9 0 DRAWINGS AND PARTS LIST 10 0 WARRANTY ...

Page 4: ... injury 2 0 SAFETY This portable decontamination system can be used in potentially dangerous situations The following must be observed at all times WARNING Avoid directing agent onto the faces of yourself and other personnel Improper use of agent could result in death or serious injury including damage to the eyes To reduce the chance of injury have yourself and other personnel wear eye protection...

Page 5: ...sing operations The DECON pak is not intended to be used for Class A Class B or any other type of foam concentrate If you intend to use the DECON pak for liquids other than decontamination agents and water we urge you to contact Task Force Tips Service Department at 800 854 6864 The use of other liquids may void the warranty and subject the user to hazards not addressed in this manual The user ass...

Page 6: ...ate The more viscous or thick the agent concentrate the greater the amount of energy required to draw the concentrate into the eductor The viscosity of most agent concentrates changes with temperature some thickening to a gel at temperatures of 40º F 4º C The DECON pak percentage knob was calibrated with ZepPowerPlex Heavy Duty Laundry Detergent Actual agent concentrations vary with changes in wat...

Page 7: ...e outlet hose which is then attached to the control block Align the marks on the quick connect male fitting with the marks on the female fitting and push the two pieces together Twist the nozzle or hose one quarter turn to the right to latch the quick connect fitting 2 To remove fan nozzle remove set screw 3 Hose lengths available TFT part U HS6 U HS and U HS25 CAUTION The DECON pak s eductor will...

Page 8: ...Percentage Knob 1 Reduce pump pressure to 100 psi or less 2 Remove the nozzle and or hose from the quick connect on the front of the Control Block 3 Remove the Circle Cotters and pull out the two Pull Pins that hold the Control Unit to the tank 4 Pull straight up to remove the Control Unit and Pickup Tube from the tank 5 Make sure the Percentage Knob is NOT in the RINSE position 6 Install the Cap ...

Page 9: ...gent solution velocity too high Partially close Flow Control Agent gets thick when cold Select Another Agent 7 0 CLEAN UP AND MAINTENANCE Turn the percentage knob to the RINSE position Use the hose or hose and nozzle to rinse off the DECON pak Reset percentage knob to proper percentage when finished For years of service periodically inspect your DECON pak Make sure the hose and fan nozzle are in p...

Page 10: ...g 1 VO 022 16 Handle Plug 1 U241 17 Valve 1 U250 18 Valve Pointer Label 1 UL504 19 124 O Ring 3 VO 124 20 1 4 20x3 4 Stud 1 U223 DESCRIPTION QTY PART 21 Knob Nut 1 U221 22 Knob Spring 1 U222 23 Percent Knob Label Decon 1 UL505 D 24 Percentage Knob Decon 1 U232 25 Vinyl Cap 1 VM1030 26 Spirol Pin 1 V1900 27 Rear Venturi Insert 1 U214 28 Dog Point Screw 4 H515 29 120 O Ring 1 VO 120 30 Venturi Cap 1...

Page 11: ...C ITALIAN UL503 J TANK GRAPHIC JAPANESE UL503 P TANK GRAPHIC PORTUGUESE UL503 R TANK GRAPHIC RUSSIAN UL503 S TANK GRAPHIC SPANISH DESCRIPTION QTY PART 1 Filter Screen 1 U165 2 Filport Leash 1 U166 3 Valve Umbrella 2 VM4290 4 Screen On Lid 1 U170 5 Lid Label 1 UL506 D 6 Fill Port Handle 1 U161 7 Name Label 1 UL521 D 8 10 16 x 5 8 SS Screw 2 VT10 16PH625 9 SS Washers 3 VW500X203 60 10 Tank 1 U100 GR...

Page 12: ...price of the equipment less reasonable depreciation in complete discharge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended beneficiary ...

Reviews: