10.0 DRAWINGS AND PARTS LIST

1

11

3

3

37

38

39

4

4

5

6

7

8

9

11

10

11

12

13

14

16

17

18

15

20

21

23

22

24

19

1

11

25

29

30

26

27

31

32

33

34

28

28

36

35

28

#

1

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

QTY

2

21

1

1

1

1

1

1

1

4

1

1

1

1

1

1

1

3

1

1

1

DESCRIPTION

Pull Pin

3/16 SS Balls

1/4-28 x 1/2 Set Screw

1.0 Hose Gasket

1.0 Coupling*

1.5 Hose Gasket

Angled Swivel

Quad Seal

Rear Block

Circle Cotter

024 O-Ring

Handle

Flow Label

022 O-Ring

Handle Plug

Valve

Valve Pointer Label

124 O-Ring

1/4-20x3/4 Stud

Knob Nut

Knob Spring

PART #

U180

V2120

VT25-28SS500

V3040

U260*

V3030

U265

VOQ-4316

U270

U182

VO-024

U240

UL500

VO-022

U241

U250

UL504

VO-124

U223

U221

U222

#

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

QTY

1

1

1

1

1

4

1

1

1

1

1

1

1

2

1

1

34

DESCRIPTION

Percent Knob Label

Percentage Knob

Vinyl Cap

Spirol Pin

Rear Venturi Insert

Dog Point Screw

120 O-Ring

Venturi Cap

Cable Assembly

Cup Seal

Front Venturi Insert

Control Block

Foam Pick Up Tube

Follower

1.5 Coupling *

Port Plug

3/16 SS Balls

PART #

UL505

U230

VM1030

V1900

U214

H515

VO-120

U213

VM1020

U212

U210

U200

U202

U251

F10010*

B770

V2120

* Specify Coupling Type

WATERWAY SUBASSEMBLY

PART #U800

Summary of Contents for PRO/pak

Page 1: ...n manual before use Operation of this device without understanding the manual and receiving proper training is a misuse of this equipment Users who have not read and understood all operating and safet...

Page 2: ...ot used at the correct percentage Make sure that the Percentage Make sure that the foam concentrate in the foam tank is the right type for the situation Do not use Class A foam on Class B fires or Cla...

Page 3: ...n area greater than 120 square feet 10 x 12 feet or 11 square meters The PRO pak should not be used on burning Polar Solvents with an area greater than 60 square feet 6 x 10 feet or 5 5 square meters...

Page 4: ...ersal Gold AFFF concentrate The Control Block and Valve Assembly can be mounted on the Foam Tank for right or left hand operation To switch hands remove the Shoulder Strap from the Pull Pins Remove th...

Page 5: ...TION MOP UP OVERHAUL OPERATIONS Apply with MEDIUM EXPANSION NOZZLE for vapor suppression Apply with MEDIUM EXPANSION NOZLE for vapor suppression 4 2 CLASS B FOAM LIQUID FUEL CLASS B HYDROCARBONS Fuels...

Page 6: ...solutions Foam expansion will be negligible It should be used where maximum reach or penetration is desired 5 0 NOZZLE SELECTION Straight Stream Low Expansion Reach 37 ft 100 psi 11 m 6 8 bar Reach 5...

Page 7: ...12 and U HS25 6 3 CONNECT DISCHARGE HOSE AND NOZZLE The PRO pak s eductor will not work if the backpressure from the outlet hose or nozzle is too high The 25 7 5m U HS25 optional hose is the maximum l...

Page 8: ...ce pump pressure to 100 psi or less 2 Remove the nozzle and or hose from the quick connect on the front of the Control Block 3 Remove the Circle Cotters and pull out the two Pull Pins that hold the Co...

Page 9: ...IFICATIONS Turn the percentage knob to the OFF position Use the hose or hose and straight stream nozzle to rinse off the PRO pak Reset percentage knob to proper percentage when finished For years of s...

Page 10: ...r Label 124 O Ring 1 4 20x3 4 Stud Knob Nut Knob Spring PART U180 V2120 VT25 28SS500 V3040 U260 V3030 U265 VOQ 4316 U270 U182 VO 024 U240 UL500 VO 022 U241 U250 UL504 VO 124 U223 U221 U222 23 24 25 26...

Page 11: ...65 U166 VM4290 U170 UL501 U161 UL521 VT10 24BH625 VW500X203 60 U100 Specify Language using identification number on tank graphic TANK SUBASSEMBLY PART U805 1 2 3 4 5 6 7 8 9 10 3 XXXX UL503 TANK GRAPH...

Page 12: ...iens and encumbrances This is a limited warranty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended beneficiary of the equipme...

Reviews: