J9020/J9030
<Treatment 1>
The function can be stopped after setting is OFF.
< Treatment 2>
If the user request below demand, Keep U460 set ON and do not stop this detection function.
a. Reduce the original damage in case of setting the stapled originals wrongly on DP.
b. Prevent missing page due to multi feeding (except DF-771)
Download the firmware
higher than Service Upgrade
Pack Ver. V3.03
[
System menu]
[Common]
[Error handling setting]
[Original skew or multi feeding]
Check firmware version by U019
MAIN
:
Ver.003.077
MMI
:
Ver.003.074
Output the maintenance report from the maintenance mode U000 and if the count of J9020
(
skew original feed
detection))/J9030(muti feeding detection) *1 is frequent, perform below either treatment 1 or 2.
*1
DP-771 has no
J9030 detection function.
Before
Higher
Detect
Stop the function
[Stop feeding by error ]
[Ignore]
User can be selected whether set on this detection function.
Perform the maintenance mode U460 (Adjust Feed Sensor ) to stop this detection function.
<Procedure> (It can be performed when DP is installed.)
[U460 Adjust Feed Sensor]
[DP]
[on/off Config]
[ON
OFF]
[Start
]
67
Summary of Contents for 6500i
Page 48: ... The film attached procedure J49XX J50XX J51XX J600X 3 9 48 ...
Page 52: ... Replacement procedure for the bushing J49XX J50XX J51XX J600X 7 9 52 ...
Page 57: ... The film attached procedure J6100 J6110 DF 3 6 57 ...
Page 71: ... The film attached procedure Corner Folding 3 6 71 ...
Page 73: ...Corner Folding 5 6 73 ...
Page 74: ...Corner Folding 6 6 74 ...
Page 103: ...Abnormal sound from the fuser section 3 5 For 3500i 4500i 5500i 103 ...
Page 104: ...Abnormal sound from the fuser section 4 5 For 3500i 4500i 5500i 104 ...