GTS
Technical Manual
9. April 2021
Edition: V1.00/2021
6-34
Copyright © 2020, Diversey
ST.08.16 error codes overview - 2100_4000_5000_3500µicro_V1.40.fm
6.7
Error codes
6.7.1
Error codes overview
The following information is only for TASKI swingo 2100µicro the new 4000/5000 and AERO 3500µicro.
In the case of the TASKI swingo 4000/5000 it is valid as of serial number 10000.
Remarks
The generated error codes will be written into the error buffer.
Display information is only possible if machine is ON.
.
Error codes
Function
Control
Machine status
Display
informa
-
tion
101
Over temperature
Temperature of power electronics is over 75°C and there
-
fore the machine is switched OFF.
If error is consistent an exchange of power electronics is
necessary.
Machine shuts OFF
E0101
109
Brake
Short circuit has been detected.
Check brake, wires and connections.
Aggregates are
turned OFF and ma
-
chine stops
E0109
Table 4: Error codes overview
Summary of Contents for AERO 3500 micro
Page 1: ...Edition V1 00 2021 Technical Manual ...
Page 5: ...9 April 2021 Edition V1 00 2021 Copyright 2020 Diversey Technical Manual 1 Forward ...
Page 8: ...9 April 2021 Edition V1 00 2021 Copyright 2020 Diversey Technical Manual 2 Elementary ...
Page 11: ...9 April 2021 Edition V1 00 2021 Copyright 2020 Diversey Technical Manual 3 General ...
Page 15: ...9 April 2021 Edition V1 00 2021 Copyright 2020 Diversey Technical Manual 4 Technical data ...
Page 24: ...9 April 2021 Edition V1 00 2021 Copyright 2020 Diversey Technical Manual 5 Mechanical ...
Page 96: ...9 April 2021 Edition V1 00 2021 Copyright 2020 Diversey Technical Manual 6 Electrical ...
Page 145: ...9 April 2021 Edition V1 00 2021 Copyright 2020 Diversey Technical Manual 8 Revision ...
Page 147: ...9 April 2021 Edition V1 00 2021 Copyright 2020 Diversey Technical Manual 9 Appendix ...