21
Maintenance of batteries (wet batteries)
Daily, after charging:
Monthly, after charging:
Preparation for use after charging:
Closing battery compartment:
Caution:
Observe the operating instructions of the battery manufacturer!
t
Measure the acidity in 3 or 4 cells.
It should be approx. 30° Bé.
The batteries are discharged when the acidity is reduced to approx. 18° Bé.
t
Please enlist the measurements into the booklet.
t
Please check the electrolyte, and if needed, fill it with distilled or desalinated
water up to 10mm above the separators.
t
Measure the acidity in every cell.
t
Please enlist the measurements into the booklet.
t
Check:
-Connectors, cable, cable connections and the poles are screwed-in tightly.
t
Return tank in position for charging.
t
Close the tank lid and fold the driver's seat back.