23
Blades replacement
Blade on the inside radius
Blade at outer radius
t
Place the clean squeegee unit with the outer radius face down on a solid
surface table, floor etc.
t
Press one hand onto the squeegee body at the hose connector.
t
Grasp the blade with your thumb and forefinger in the middle of the arch and
pull strongly until the metal band clicks open and the blade is released from
the squeegee body.
t
Release the metal strap and pull the blade off the squeegee body.
t
Clean squeegee (body, metal straps and blads) with a brush.
t
Mount the "rotated" or replaced blade onto the squeegee body.
t
Lock the metal strap (Check position of mounting slots) into place and press
onto the centre of it until it clicks into place and presses the blade onto the
squeegee body (Risk of injury).
t
Place the squeegee onto the hose connector and the bumper wheels.
t
Release the metal band by loosening the fixation screw (torx).
t
Release the metal band and pull the blade off the squeegee body.
t
Clean squeegee (body, metal straps and blads) with a brush.
t
Mount the "rotated" or replaced blade onto the squeegee body.
t
Hook the metal strap into place (Check position of mounting slots) and fix
it with the screw until the blade is pressed onto the squeegee body.
t
The shape of the blades allow them to be used on all sides before needing
replacement.