51
Malfunctions
Technical data
Malfunction
Possible causes
Troubleshooting
Page
Machine without function
Machine is switched off
• Switch on the main switch
No power supply
• Insert the plug into the mains sock
-
et
Main cord defect
• Replace the main cord
Motor does not turn
• Contact your service partner
Defective safety switch
• Contact your service partner
Tool does not rotate
Motor runs, but tool does not rotate
• Drive belt torn or loose
• Contact your service partner
Defective electronic component
• Contact your service partner
Machine has no function, indicator
light is on
Machine overload, overload switch
was activated
• Wait a few minutes and try again
(overload switch resets automati
-
cally)
Machine does not reach nominal
speed, overcurrent is activated
Machine overload
• Check the work technique
Undervoltage: Main cord is too long
• Remove power supply cord exten
-
sion
• Check the voltage rating
Machine does not run smoothly
Pad deformed or damaged
• Replace pad
Spray pump is running, cleaning
product is not released
Cleaning product dried in the spray
unit or hose blocked
• Clean spray unit
• Replace spray unit
Machine
1200
Working width
50
cm
Dimensions (LxWxH)
95 x 52 x 118
cm
Maximum weight of operational machine
44
kg
Rated voltage
230-240V~
220V~
120V~
AC
Frequency
50
60
Hz
Rated power, nominal
1300
1200
W
Rated power, additional outlet
700
W
Values according to IEC 60335-2-67
Sound pressure level LpA
63
dB(A)
Uncertainty KpA
2.5
dB(A)
Vibration
<2.5
m/s2
Uncertainty K
0.25
m/s2
Splash water guard
IPX0
Protection class
I
EN