background image

www.tasking.com

Hardware Setup and Configuration

For detailed visual presentation of the hardware setup and configuration, refer to the 

Get-

ting started Tutorial

 - use the link isystem.com/start.

1. Connect the power supply cable. BlueBox should be switched off.

2. First connect the BlueBox to the PC via USB cable. Later you can configure TCP/IP connection to
work remotely. 

3. Connect the Grounding wire to the BlueBox and the Target. 

If  the  Grounding  wire  is  not  connected,  the  ground  potential  difference  between  the
BlueBox and the Target can exceed well over 1000V even before any of the  devices  are
powered up. This voltage difference is discharged over the BlueBox and the Target, lead-
ing to the possible destruction of electronic components.

4. Connect FNet cable of Active Probe to the BlueBlux FNet port.

5. Connect Active Probe's ribbon cable(s) to the Target.

Although  it  looks  similar  to  the  HDMI  interface,  the  FNet  Port  is  not  compatible  with
HDMI or any HDMI accessories.
Connecting the hardware to HDMI accessories will damage the hardware and will render
the hardware warranty void.

6. Power ON the hardware in the following order:

a. BlueBox
b. Target

7. Install winIDEA and create a new workspace. 

8. Configure Debug channel modes via 

Hardware / CPU Options / SoC

.

For troubleshooting refer to Knowledge Base - use the link kb.isystem.com.

More general settings are described in 

winIDEA Help

.

Summary of Contents for MPC5X

Page 1: ...www tasking com MPC5X SPC5X AURORA ACTIVE PROBE HARDWARE USER MANUAL V2 2 March 2024...

Page 2: ...avoid potential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Ensure proper protection to avoid exposing the BlueBox device or the...

Page 3: ...www tasking com Contents Package content 4 Specifications 5 Device description 6 mDIO Cable 8 14 pin 2 54mm JTAG Converter 9 Hardware Setup and Configuration 10 Accessories 11...

Page 4: ...www tasking com Package content The MPC5x SPC5x Aurora Active Probe is delivered with the following components MPC5x SPC5x Active Probe 1m FNet Cable Ordering code IC57150 Ordering code BB FNET 100...

Page 5: ...ength 31 cm OPERATION Communication inter face to BlueBox TASKING proprietary FNet Debug signal valid input voltage range 3 3V max 3 6V Power consumption Max 1 5W dependent on operation mode Number of...

Page 6: ...D Ground Not Connected NC 25 26 AGBT CLK_P AGBT Clock O Not Connected NC 27 28 AGBT CLK_N AGBT Clock O Ground GND 29 30 GND Ground Not Connected NC 31 32 NC Not Connected Not Connected NC 33 34 NC Not...

Page 7: ...reen Powered on and ready to use Blinking green Establishing connection with the BlueBox Blinking blue Reprogramming SPLASH Permanently magenta Golden image loaded and ready to use D FNet connector th...

Page 8: ...ead or controlled by the debugger For example the de bugger can periodically service an external watchdog through the mDIO output or just read and re cord an external signal through the mDIO input It...

Page 9: ...ORESET Power On Re set O IO Reset nRESET 9 10 TMS JTAG O I Reference Voltage Vref 11 12 GND Ground Not Connected NC 13 14 nJCOMP JTAG TRST op tional O 14 pin 2 54mm MPC5xxx SPC5 pinout Signal Directio...

Page 10: ...s are powered up This voltage difference is discharged over the BlueBox and the Target lead ing to the possible destruction of electronic components 4 Connect FNet cable of Active Probe to the BlueBlu...

Page 11: ...MPC5x SPC5x Aurora Active Probe IC57150 Infineon SGBT HSTCU Active Probe IC57166 RH850 Aurora Active Probe IC57176 MPC5x SPC5x Active Probe Accessories Description Ordering Code 1 0m FNet Cable BB FN...

Page 12: ...www tasking com www tasking com Visit our website for Support isystem com support Tutorials isystem com start Knowledge Base kb isystem com...