8

CONTROL relay is turned on.

 

upper sensor of WAW

 

                                   lower sensor of WAW

 

fireplace sensor

 

      80

 o

  

73

 o

   68

 o

 

If the summer mode is active (only WAW), SUMMER replaces CH.
It’s a stable screen that is in order to change it one needs to press the CHOOSE button

Screen of fireplace operation mode

 

Firp.MOD 

 

    

AUTO

 

9

 

ModeWAW   

    

SUMMER

 

 Screen of clock

 

CLOCK $1

 

   

17:15

 

 

Menu

 

       

0

 

Screen of setting the parameters

Screen of whole system operation

On the screen are the symbols of devices:
Firplace- fireplace
CH - central heating system
WAW - Warm Applicable  Water accumulator
* - if the relay is switched on

The  symbols  (every  few  seconds  or  after  pressing  CHOOSE  button)  are  replaced  with  numbers 
presenting the temperatures of those devices.
The blinking arrows mean the actual heat flow as an effect of pumps operation:
Firplace->WAW the pump P1supplying the WAW accumulator is turned on.
Firplace->CH the pump P3 is turned on.

There are the following modes:

ON

The throttle is automatically controlled to stabilize temperature of the water jacket
Green status lamp lights (7)

AUTO Automatic operation is activated by pressing the “ON/OFF” button (6). The throttle is fully 

open. In 2hrs a fireplace ought to heat itself and reach the set temperature stabilized by 

  o

throttle  movements.  From  that  moment  the  temperature  fall  by  more  than  10 C 
(”

T.FirOFF

”  parameter)  existing  for  30mins  is  treated  as  a  turn-off  of  fireplace.  The 

regulator  ends  an  operation  cyclesetting  the  throttle  at  rest  position.  Pressing  the 
“ON/OFF” button once more starts another operation cycle.

Green status lamp (7) lights during fireplace operation and turns off after recognizing the 

turn-off state of fireplace.

OFF

Setting the throttle at rest position (defined by the  “

ModeOFF

” parameter).

Green status lamp (7) doesn’t light

MAN

Automatic control blocked - only manual control is available
Green status lamp (7) blinks.

It’s a unstable state that is   after 10secs from the last press of any button the screen changes to the 
screen of fireplace temperature measurement. All the next screens are unstable.

Screen of WAW operation mode

In  the  regulator  one  can  set  “

ModeWAW

”  parameter  achieving  different  strategies  of  operation. 

Possible modes are:

OFF - 

The pump WAW turned off

SUMMER-

  Turning  off  the  heating  system  in  summer  time  (the  pump  CH  doesn’t  operate). 

Fireplace only works in the preparation function WAW.

ON - 

Standard operation (parallel operation of pumps) without favouring the WAW circuit

PRIO-

Faster  reaching  the  readiness  of  WAW  accumulator    by  limiting  heat  obtain  by  heating 

system. The pump CH works cyclically. Turning off the pump WAW after supplying the accumulator 
causes the comeback of normal operation of the pump CH

CLOCK-

beyond time zones the pump operates like in the ON mode and in the time zone like PRIO

The screen shows the actual time and the number of active time zone.

Time correction is possible after pressing the CONFIRM button (5) and the minutes field begins 
blinking. The blinking value can be altered with the buttons “+” or “-”. Pressing the CHOOSE button 
(3) one comes to the hours field that can be set with the buttons “+” or “-”. 
Pressing the CONFIRM button confirms the changes (the clock field will stop blinking).

Normally the parameters setting level equals to “0” namely the parameters aren’t available. 
After changing the level to “1”, “2” or “3” successive screens show the values of parameters.
The last screen contains “****” after which it comes back to the above mentioned screens.

Firplace->WAW

Summary of Contents for RT-08P

Page 1: ...control a throttle drive 1 5V 500mA DC o Number of water temperature sensors 3 KTY81 0 100 C o Temp measurement precision 2 C o Temp measurement resolution 0 5 C Number of time zones 4 Zak ad elektro...

Page 2: ...water accumulator WAW The pump operates if fireplace temperature both exceeds the ONWAW value and is higher than the WAW accumulator temperature T2 by the DeltaWAW parameter see LEVELPARAMETERS1 The t...

Page 3: ...r house usage and the like Part 1 General requirements PN EN 55022 2000 Electromagnetic compatibility EMC IT devices Characteristics of radioelectric noises Acceptable levels and measurement methods C...

Page 4: ...Burnt fuses arenot subject towarranty replacement Register No GIOS E 0002240WZ Worn out electronic and electric devices must be transfered to the utilization collection place where will be accepted fo...

Page 5: ...ymoreprecisely seePARAMETERSofLEVEL3 There are elements on the control panel fig 2 In the turn off state only the orange lamp 7 lights indicatingthe standby mode The turn on of the regulator follows b...

Page 6: ...g the throttle position in power off state parameter of level 3 Press repeatedly CHOOSE button till the Menu 0 parameter setting screen appears CONFIRM button 0 starts blinking threefold button 3 blin...

Page 7: ...n of the relay CONTROL if 1 fireplace temperature is higher than T CH ON 2 fireplace temperature is higher than T WAW ON 3 4 T minWAW 5 T maxWAW 6 fireplace temperature is higher than T Alarm NAME T F...

Page 8: ...ing the turn offstateoffireplace OFF Settingthethrottleatrestposition definedbythe ModeOFF parameter Greenstatuslamp 7 doesn tlight MAN Automaticcontrolblocked onlymanualcontrolisavailable Greenstatus...

Reviews: