USER MANUAL
program version 2.1 (06.02.2014
)
from program v2.1
RT-14
CONTROLLER OF HEATING SYSTEM
WITH SOLID FUEL BOILER
RT14/2014/v.2.1/ANG
1.Basic parameters
Power
Number of outputs to control pumps
Number of outputs to control the valve motor
Number of temperature sensors of water
Switch-on temperature of the STB safety thermostat
94 C
230V/50Hz
Power consumption without load
4W
Max connection power
750W
Operation conditions
0-50 C, humidity10-90%
no condensation
Housing protection class
IP41
Fuse
6,3A/250V
P
of blower output
1,5A/230V/50Hz
3 * 200W/230V/50Hz
2 * 200W/230V/50Hz
3 * KTY81 (0...+100 C )
Temperature sensor of the flue gas
PT1000 (-30...+450 C)
Temp. measurement precision
+/- 1 C
Temp. measurement resolution
0,1 C
o
o
o
o
o
ower-carrying capacity
o
The controller controls the heating system based on the solid fuel boiler in which by controlling the
efficiency of the blower the burning process is under control. The receivers of the heat are as follows:
Container of the Warm Applicable Water (WAW) and Heating System (CH). The controller
cooperates with the 3-way mixing valve in the heater or floor system and safety system of the return
temperature of the boiler.