VERTICAL TOWED MIXER - TWO AUGERS
MV-30D SERIES
Hydraulic front jack
Tl
Ta
Periodically check the oil level with the overflow plug (Tr) and top
up if necessary, with the plug (Tl).
To change the oil, release the tank by loosening the clamp (Ta).
Tr
GREASING
All the movement points and transmissions of the mixer must be cleaned and
lubricated weekly, using the lubricators commented for this purpose. It is convenient
somebody with a certain experience observe the behavior of such points.
The lubrication points are duly marked by the label shown in the figure.
Do not over-lubricate, especially if a compressed air pump is used. This in
order to avoid damaging the bearing seals. Lithium grease of proven
quality should be used.
PAY SPECIAL ATTENTION TO THE PTO SHAFTS.
Lubricate them every 50 hours.
Pump the grease into the crosshead til it comes out through the seals.
Pump the grease progressively.
Manual pumps generally provide 0.8 - 1.0 grams of grease per pump
1 ounce (oz) = 28.3 grams (g)
Tatoma Ag Equipments Corp. Located in Colcord, OK. Phone (918) 422-4271
- 69 -