VERTICAL TOWED MIXER - TWO AUGERS
MV-30D SERIES
INCIDENCE
The screen does not light
up or the indication Lo-
bAT shows up on the
screen
You turn on the screen
and Er-OuT shows up.
POSSIBLE CAUSE
Weight system
- Blown protection fuse
- Inverted connection
- Rusty, dirty or spoiled
tractor plug
- Low battery
- Cable cut
- Short circuit alarm or
scale malfunction
REPAIR
- Clean the plug or change
it
- Charge the battery
- Connect the cable
- Check that the cables are
well insulated, and check
the operation of the scale
The scale does not weigh - Error in the assembly of - Check that there is no
correctlythe cellssupport point between
- Possible point of contact tank and chassis or axle
between the chassis or and correct
axle and the tank.- Check the calibration
- Incorrect calibration
value
You see on the display:- Unregulated tare system - Adjust the tare weight
Cxxxx-Lwith the instructions in
Cxxxx-Hthe manual.
You see on the display:- Broken cell cable or bad - Check the connection in
Or-Lground, or possible cell the box, check the cell
Or-Hbroken by knocks or cables, or check if there is
deformationa faulty cell (1)
(1) To check if there are any cells that have failed, first disconnect all of them and
then connect one by one and take the data that appears on the screen. If any of the
above symbols appears, it will indicate that the cell is broken
Tatoma Ag Equipments Corp. Located in Colcord, OK. Phone (918) 422-4271