CNG
dispensers
TATSUNO
EUROPE
‐
Quick
User
Guide
,
revision
01,
March
2022
25
4.1.9.
DISPLAYING
THE
PROGRAM
VERSION
AND
CHECK
SUMS
(P05)
This
function
shows
the
number
of
the
program
version
of
the
dispenser
counter
and
different
check
sums.
These
values
are
intended
for
metrology
authorities
and
authorized
service
engineers.
The
meaning
of
the
individual
parameters
is
described
in
the
table
below.
Parameter
Meaning
Parameter
Meaning
P05
‐
1
Version
of
program's
metrology
parts
P05
‐
5
Check
sum
(CRC)
of
the
parameter
memory
P05
‐
2
Metrology
check
sum
(CRC)
of
the
program
P05
‐
6
Check
sum
(CRC)
of
the
device
for
temperature
compensation
P05
‐
3
Release
number
(C
+
number),
program
version
P05
‐
7
Time
and
date
of
program
creation
(e.g.,
07:56:17,
19.
07.
2011)
P05
‐
4
Total
check
sum
(CRC)
of
the
program
NOTE
Metrologically
relevant
data
P05
‐
1
and
P05
‐
2
also
appear
on
the
display
for
a
while
after
the
power
on.
NOTE
The
calculated
CRC
(cyclic
redundancy
sum)
values
are
checked
after
switching
on.
If
the
calculated
checksum
is
different
from
the
stored
correct
sum,
the
dispenser
is
blocked
and
error
message
E13
is
displayed.
Higher
cyclic
checksum
orders
are
displayed
on
the
amount
line,
lower
orders
on
the
quantity
line.
The
CRC
of
the
peripheral
unit
programs
(PDEINP
and
PDEDPS)
is
checked
before
each
delivery
is
enabled.
If
the
calculated
value
of
the
peripheral
unit
checksum
does
not
match
the
correct
value,
delivery
(fuelling,
pumping)
is
not
started
and
the
corresponding
error
message
is
displayed.
4.1.10.
ERROR
MESSAGE
CODES
HISTORY
(P06)
The
function
is
used
to
display
the
history
of
the
last
100
error
message
codes
that
have
occurred
and
displayed
on
the
dispenser.
The
table
of
error
messages
codes
is
given
in
chapter
6.2.1.
After
switching
to
parameter
P06,
the
display
shows
the
code
of
the
last
error
message
(e.g.,
E30
zero
unit
price).
After
pressing
the
<E>
key,
the
date
and
time
of
the
fault
will
be
displayed.
After
pressing
the
<+>
key,
the
code
of
the
penultimate
error
message
code,
etc.
appears
on
the
display.
Parameter
Meaning
P6
‐
00
code
of
the
last
error
P6
‐
01
code
of
the
penultimate
error
…
…
P6
‐
98
99th
error
code
in
the
sequence
P6
‐
99
100th
error
code
in
the
sequence
NOTE
If
two
identical
error
message
code
occur
in
a
row,
then
only
the
last
one
is
displayed.
4.1.11.
LAST
FUELLING
HISTORY
(P07)
The
parameter
is
used
to
display
the
last
50
fuellings
(deliveries).
After
switching
to
parameter
P07
the
display
shows
the
last
fuelling
transaction.
The
transaction
price
with
the
parameter
number
flashes
on
the
unite
price
display.
After
pressing
the
<+>
key,
the
penultimate
fuelling…,
etc.
appears.
After
pressing
the
<E>
key,
the
date
and
time
of
the
end
of
the
saved
fuelling
will
appear
on
the
display.
Parameter
Meaning
P6
‐
00
Last
fuelling
P6
‐
01
Penultimate
fuelling
…
…
P6
‐
48
49
th
last
fuelling
in
the
sequence
P6
‐
49
50
th
last
fuelling
in
the
sequence
Example:
Last
fuelling
at
filling
point
A
had
a
value
of
11.66
L,
9.46
€,
0.811
€/L
and
was
terminated
23.8.2021
at
9:47:06
4.1.12.
MANAGER
MODE
ACCESS
PASSWORD
(P08)
INFO
4092
P05
‐
2
<E>
E>
Err
30
P6
‐
00
230821
094706
P6
‐
00
946
1166
‚25
‐
00‘
946
1166
‚0811‘
<E>
<E>
946
1166
25
‐
00
230821
094706
25
‐
00