NOTICE
After
start
‐
up
of
calculator
TBELTM
and
before
every
delivery
transaction
are
checked
values
of
the
registers
inside
mass
meter
if
they
are
equal
with
values
saved
in
calculator
memory.
If
not,
error
code
E74
is
appeared
on
display
and
delivery
is
not
allowed.
To
disable
the
error
is
necessary
to
perform
function
P99
=
4444
again.
NOTICE
To
run
function
mass
meter
configuration
is
necessary
to
press
<R>
on
yellow
service
remote
transmitter
PDERT
‐
5S,
enter
service
password
(factory
setting
11111111)
followed
by
key
<E>.
In
Service
mode
of
calculator
is
necessary
to
press
99
with
<E>
to
go
on
parameter
99
and
after
press
<E>
again,
enter
value
4444
and
<E>.
If
function
passed
OK
then
message
„done
“appeared
for
a
while.
5.3.
DISPENSER
OPERATION
NOTICE
The
operator
is
responsible
for
the
operation
of
the
fuel
station
and
it
is
his
duty
to
monitor
the
delivery
of
fuel
and,
in
the
event
that
the
customer
performs
unauthorized
operations
at
the
self
‐
service
dispensers,
he
must
instruct
the
customer
about
proper
handling.
The
operator
is
also
obliged
to
mark
the
risk
area
of
the
fuel
station
with
warning
symbols
(smoking
ban,
ban
on
open
fire,
direction
of
arrival
to
the
dispenser,
etc.).
The
fuel
station
operating
instructions
must
be
freely
accessible
to
the
customer
for
any
information
on
basic
obligations.
5.3.1.
CNG
DELIVERY
TO
MOTOR
VEHICLES
Delivery
start
Before
the
delivery
starts,
the
dispenser
attendant
checks
whether
the
storage
tank
in
a
vehicle
has
a
homologation
mark,
the
vehicle
engine
and
all
electrical
devices
are
turned
off.
Then
he/she
visually
inspects
the
condition
or
wear
of
the
filling
neck/connector
that
could
be
the
reason
for
leaks.
If
he/she
finds
serious
deficiencies,
he/she
is
entitled
to
refuse
storage
tank
filling.
In
case
of
gas
leak
or
danger
the
attendant
shall
finish
the
delivery.
The
operation
of
the
dispenser
itself
is
ensured
by
the
employee
of
the
fuel
station
who
lifts
the
delivery
nozzle
from
the
dispenser
and
connects
it
to
the
storage
tank
of
the
vehicle
which
must
be
secured
against
moving.
Immediately
after
the
nozzle
is
lifted
the
display
test
is
performed
–
displaying
all
segments
–
and
then
it
is
reset
and
the
product
unit
price
is
displayed.
After
pressing
the
START
button
located
on
the
counter
case
the
electromagnetic
valve
opens
at
the
inlet
of
the
first
pressure
section
and
the
pressure
storage
tank
of
the
vehicle
is
filled
with
compressed
natural
gas.
In
the
moment
when
the
delivery
speed
decreases
under
the
defined
limit,
the
electronic
counter
automatically
switches
delivery
to
the
second
section
and
then
potentially
to
the
third
pressure
section
–
depending
on
the
dispenser
and
fuel
station
configuration.
NOTE
Some
dispensers,
especially
non
‐
public
‐
company
dispensers,
are
not
fitted
with
the
sensors
of
delivery
nozzle
lifting.
At
such
dispensers,
the
display
test
is
performed
after
pressing
the
START
button.
Delivery
termination
The
delivery
may
be
terminated
for
various
causes.
Possible
causes
of
delivery
termination
and
corresponding
messages
shown
on
the
display
are
mentioned
in
table
below
Table
4
‐
Causes
for
delivery
termination
Event
Indication
on
display
1.
Pressing
the
STOP
button
by
the
customer/attendant
during
the
delivery
STOP
2.
Attaining
the
pre
‐
set
sum,
quantity,
or
limit
values
of
the
dispenser
STOP
3.
STOP
command
received
from
the
superior
system
(payment
terminal)
STOP
4.
Gas
flow
rate
drop
under
the
value
set
on
the
dispenser
(e.g.,
<
2kg/min)
FULL
5.
Attaining
the
maximum
possible
mass
calculated
by
temperature
compensation
FULL
6.
Detection
of
an
error
event.
Exx
8888888
1888888
88888
0.0
0.000