background image

TATSUNO

 

EUROPE

 

a.s.,

 

www.tatsuno

europe.com

 

 

 

34

The

 

LCD

 

display

 

consists

 

of

 

the

 

following

 

parts:

 

Display

 

segment

 

Function

 

Note

 

 

Amount

 

delivered

 

‐ 

for

 

P12=0

 

it

 

can

 

display

 

the

 

value

 

from

 

 

0

 

to

 

99999.9

 

‐ 

for

 

P12=1

 

it

 

can

 

display

 

the

 

value

 

from

 

 

0

 

to

 

999999.9

  

 

 

Volume

 

delivered

 

‐ 

for

 

P12=0

 

it

 

can

 

display

 

the

 

value

 

from

 

0

 

to

 

9999.99

 

kg

  

‐ 

for

 

P12=1

 

it

 

can

 

display

 

the

 

value

 

from

 

0

 

to

 

99999.99

 

kg

  

 

 

Delivered

 

fuel

 

unit

 

price

 

‐ 

for

 

P12=0

 

it

 

can

 

display

 

the

 

value

 

from

 

0

 

to

 

99.99

 

€/kg

  

‐ 

for

 

P12=1

 

it

 

can

 

display

 

the

 

value

 

from

 

0

 

to

 

999.99

 

€/kg

  

 

 

   

Dispenser

 

status

 

indication

 ‐ 

released

 

for

 

delivery

 

/

 

blocked

 

‐ 

it

 

appears

 

automatically

 

when

 

the

 

dispenser

 

status

 

changes

 

    

Signalling

 

of

 

forced

 

termination

 

of

 

delivery

 

‐ 

it

 

appears

 

after

 

the

 

STOP

 

command

 

has

 

been

 

received

 

from

 

the

 

booth,

 

after

 

the

 

preset

 

number

 

/

 

preset

 

amount

 

has

 

been

 

reached

 

or

 

after

 

the

 

allowed

 

time

 

without

 

delivery

 

has

 

been

 

exceeded

 

    

Fault

 

signalling

 

or

 

maintenance

 

required.

 

‐ 

it

 

will

 

be

 

displayed

 

at

 

each

 

fault

 

indication

 

together

 

with

 

the

 

fault

 

code

 

(see

 

6.2.1)

 

5.3.6.

 

DISPENSER

 

OPERATION

 

TERMINATION

 

After

 

switching

 

off

 

the

 

power

 

supply

 

of

 

the

 

electronics

 

in

 

the

 

fuel

 

station

 

switchboard,

 

the

 

“OFF”

 

message

 

is

 

displayed

 

on

 

the

 

unit

 

price

 

display

 

and

 

the

 

display

 

illumination

 

switches

 

off.

 

The

 

last

 

data

 

is

 

shows

 

on

 

the

 

display

 

for

 

at

 

least

 

15

 

minutes

 

after

 

the

 

power

 

supply

 

disconnection.

 

After

 

elapsing

 

this

 

period

 

and

 

“erasing”

 

the

 

display

 

the

 

display

 

status

 

is

 

saved

 

into

 

the

 

counter

 

memory

 

and

 

will

 

be

 

shown

 

after

 

the

 

power

 

supply

 

is

 

connected

 

again

 

 

see

 

the

 

previous

 

section.

  

Now

 

the

 

dispenser

 

is

 

out

 

of

 

order.

 

6.

 

MAINTENANCE

 

AND

 

SERVICE

 

6.1.

 

MAIN

 

PRINCIPLES

 

OF

 

DISPENSER

 

MAINTENANCE

 

 

 

keep

 

all

 

functional

 

units

 

of

 

the

 

dispenser

 

clean

 

so

 

that

 

any

 

potential

 

unexpected

 

defect

 

may

 

be

 

easily

 

identified

 

and

 

quickly

 

removed

 

 

continuously

 

check

 

all

 

connections

 

if

 

the

 

leakage

 

of

 

the

 

fuel

 

occurs,

 

tighten

 

and

 

reinforce

 

joints

 

 

inspect

 

the

 

condition

 

of

 

the

 

delivery

 

nozzle

 

and

 

decide

 

on

 

repair

 

or

 

replacement

 

of

 

the

 

delivery

 

nozzle,

 

if

 

necessary,

 

according

 

to

 

the

 

type

 

and

 

size

 

of

 

the

 

defect

 

 

regularly

 

check

 

the

 

condition

 

of

 

the

 

delivery

 

hoses.

 

In

 

case

 

of

 

mechanical

 

damage

 

to

 

the

 

delivery

 

hose,

 

ensure

 

its

 

immediate

 

replacement.

 

 

check

 

the

 

function

 

of

 

the

 

door

 

locks

 

and

 

the

 

mechanism

 

for

 

hanging

 

the

 

delivery

 

nozzle

 

 

care

 

for

 

external

 

cleanliness

 

of

 

the

 

dispenser,

 

pay

 

special

 

attention

 

to

 

counter

 

window

 

cleanliness

 

CAUTION

 

It

 

is

 

necessary

 

to

 

always

 

switch

 

off

 

electricity

 

and

 

take

 

reliable

 

measures

 

against

 

its

 

reconnection

 

before

 

performing

 

all

 

maintenance

 

work

 

at

 

mechanical,

 

hydraulic

 

or

 

electrical

 

parts.

 

 

CAUTION

 

Do

 

not

 

remove

 

the

 

dispenser

 

covers

 

during

 

operation!

 

 

CAUTION

  

Do

 

not

 

open

 

the

 

distribution

 

box

 

lid

 

if

 

the

 

dispenser

 

is

 

live!

 

 

CAUTION

 

The

 

interventions

 

into

 

electrical

 

and

 

electronic

 

parts

 

may

 

only

 

be

 

performed

 

by

 

a

 

specialist

 

who

 

is

 

responsible

 

for

 

device

 

safety.

 

The

 

wires

 

must

 

be

 

repositioned

 

to

 

their

 

original

 

position

 

after

 

finishing

 

the

 

service

 

intervention.

 

Proper

 

fitting

 

of

 

wires

 

must

 

prevent

 

contact

 

with

 

the

 

movable

 

parts

 

of

 

the

 

reel

 

module.

 

 

406.1

 

15.32

 

 

kg

 

€/kg

 

OFF

 

Summary of Contents for EUROPE

Page 1: ...ensersUserRev01 docx Revision Date revision 01 March 2022 Number of pages 40 including cover Created by Ing Milan Berka TATSUNO EUROPE a s Pra sk 2325 68 678 01 Blansko Czech Republic tel 420 516 4284...

Page 2: ...01 Blansko Czech Republic Tel 420 516428411 Fax 420 516428410 e mail info tatsuno europe com http www tatsuno europe com Copyright Neither the manual nor any part of it may be reproduced without the e...

Page 3: ...HE DISPENSER 14 2 6 NAMEPLATES 15 3 INSTALLATION 16 3 1 INSTRUCTIONS FOR OCCUPATIONAL SAFETY 16 3 2 RECEIPT TRANSPORT UNPACKING 16 3 3 DISPENSER LOCATION 17 3 4 MECHANICAL ATTACHMENT OF THE DISPENSER...

Page 4: ...0 5 9 2018 Basic version of the document Milan Berka Revision 01 31 3 2022 Update of technical data error messages dispenser settings PDEX5 Ocean Tower CNG Milan Berka 1 INTRODUCTORY INFORMATION Symbo...

Page 5: ...the fuel station especially construction and repairs is performed fill yin compliance with this list It is the obligation of the constructor that all his employees comply with all laws directives and...

Page 6: ...For unmanned fuel stations breakaway couplings must also be used to reduce the risk in the case of departure after the delivery nozzle has been forgotten in the vehicle tank WARNING Only qualified per...

Page 7: ...les and checkthecondition of dispensers reservoirs machinery operation gas pressure and keep prescribed operating records in regular intervals Attendant s responsibilities Keep the operated devices in...

Page 8: ...for private use display only the dispensed fuel quantity in kilograms NOTICE Standard painted versions of TATSUNO EUROPE dispensers are not intended for use in high humidity chemical and saltwater ar...

Page 9: ...tic valves Two state 24VDC max 1A Data transmission of the entire contents of the display with the number of digits 7 6 5 5 is only possible using the extended communication protocol 8 8 6 2 3 DISPENS...

Page 10: ...ispenser marking and sorting system In the case of a double sided dispenser the right side of the dispenser is also referred to as side A and the left side is referred to as side B For a one sided lef...

Page 11: ...40x1 OEL R CNG 1 x 1 1 1 1x30 BMP40x1 OEL R CNG H 1 x 1 1 1 1x70 BMP40x2 OED CNG 2 x 2 2 2 2x30 BMP40x2 OED CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OED CNG H H 2 x 2 2 2 2x70 BMP40x2 OEL R CNG H 1 x 1 2 1 1...

Page 12: ...1 x 1 1 1 1x30 BMP40x1 OSL R CNG H 1 x 1 1 1 1x70 BMP40x2 OSD CNG 2 x 2 2 2 2x30 BMP40x2 OSD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OSD CNG H H 2 x 2 2 2 2x70 BMP40x2 OSL R CNG H 1 x 1 2 1 1x30 1x70 BMP40...

Page 13: ...OWL R CNG 1 x 1 1 1 1x30 BMP40x1 OWL R CNG H 1 x 1 1 1 1x70 BMP40x2 OWD CNG 2 x 2 2 2 2x30 BMP40x2 OWD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OWD CNG H H 2 x 2 2 2 2x70 BMP40x2 OWL R CNG H 1 x 1 2 1 1x30...

Page 14: ...sic parts of the WSE dispensing module and its cover Position Device Position Device Position Device 1 CNG mass meter 6 CNG hose filling 11 Nozzle cover stainless without a switch 2 CNG electromagneti...

Page 15: ...Marking of the dispenser type see section 2 3 OIML certificate Number of the OIML certificate Serial number Serial number of the dispenser seq number year of production Gas temperature range Range of...

Page 16: ...handling and transport If the transport is ensured by the customer in another way the manufacturer shall ensure professional loading However the manufacturer is not responsible for the method of trans...

Page 17: ...ce for dispenser installation must be structurally secured so that the possibility of dispenser damage by an incoming car and following medium leakage into atmosphere is avoided as best as possible Th...

Page 18: ...lling the dispenser at the filling station the following must be taken into account in particular what danger zones the dispenser creates with its operation what danger zones are created by the surrou...

Page 19: ...counters used in these dispensers are separated from other areas by a type 1 partition according to EN 13617 1 they are in an uncovered design IP54 IP55 and must therefore be located in a non explosiv...

Page 20: ...the grounding system As a grounding wire you can use a yellow green cable with a section of at least 4 mm2 or a special grounding strap The grounding wire must be connected to a central grounding term...

Page 21: ...nged using the remote IR infrared controller the service keypad or the pre set keypad buttons located on the dispenser The basic control unit of the dispenser is an electronic counter which is stored...

Page 22: ...d to set the volume amount pre selection on the dispenser Unlocking the dispenser after delivery If the dispenser is in the manual mode with the blocking after delivery you can unlock the dispenser wi...

Page 23: ...d service staff who can set a new one After entering the valid access password the display shows the value of the first parameter P00 1 Now it is possible to browse parameters by using the key or by e...

Page 24: ...er Meaning Factory setting P03 1 product unit price hose 1 0 00 Euro kg P03 2 product unit price hose 2 0 00 Euro kg NOTENumber of fuel products shown in the P03 parameter is conditioned by the config...

Page 25: ...g error message is displayed 4 1 10 ERROR MESSAGE CODES HISTORY P06 The function is used to display the history of the last 100 error message codes that have occurred and displayed on the dispenser Th...

Page 26: ...ting 12 0 Automatic mode with remote control The dispenser is remotely controlled by a computer or station controller via a data line It starts fuel delivery only when an authorization command from th...

Page 27: ...following arrangement of data on the display the first line of the display shows the temperature on the processor unit of the counter intenthsofCelsiusdegrees 26 C Thesecondlineshowsanaverageambientte...

Page 28: ...ns of all installed technical devices Do not allowpersonswithoutappropriateprofessionalqualificationtotampertheinstalledtechnology includingthegasdevices CAUTION It is forbidden to smoke and use open...

Page 29: ...service remote controller to enter the counter service mode R password Setting parameter P97 to 1 activates the zero point setting function The counter sends a command to set the zero point to the mas...

Page 30: ...serious deficiencies he she is entitled to refuse storage tank filling In case of gas leak or danger the attendant shall finish the delivery The operation of the dispenser itself is ensured by the em...

Page 31: ...tion Immediately inform the operator about each defect failure or abnormality during operation Immediately decommission the device in case of gas leak or danger Keep tidiness and cleanliness and ensur...

Page 32: ...control deliveries from the fuel station booth The booth contains a control device by which the fuel station attendant releases the dispenser for delivery and collects information about the delivered...

Page 33: ...down that ensure safe deceleration of fuel flow rate before the target preset value a Example of entering the pre selection in Euros The customer arrives to the dispenser and wants to deliver fuel for...

Page 34: ...to the counter memory and will be shown after the power supply is connected again see the previous section Now the dispenser is out of order 6 MAINTENANCE AND SERVICE 6 1 MAIN PRINCIPLES OF DISPENSER...

Page 35: ...nter season when due to the activity of aerosols from chloride agents created from salts used for road maintenance the paint of unprotected body parts may be permanently damaged or inter crystal corro...

Page 36: ...the circuit breaker for the single phase power supply 230V of the dispenser in the main switchboard of the fuel station If the dispenser is connected to the control computer the dispenser blocking may...

Page 37: ...munication Controlling computer not connected or communication cable not connected correctly E20 NFAT Power failure during delivery Check the dispenser power supply If the fault persists call an autho...

Page 38: ...witchboard the valves on the supply line must be fully closed during service work vehicles must be prevented from passing within 5 meters around a fire extinguisher must be available to workers servic...

Page 39: ...CNG dispensers TATSUNO EUROPE Quick User Guide revision 01 March 2022 39 6 3 3 EU DECLARATION OF CONFORMITY...

Page 40: ...TATSUNO EUROPE a s www tatsuno europe com 40 NOTES...