13
Terminals 9-11
= N.O. INTERNAL RADAR input. Commands the door opening function.
It is inhibited by digital selector DOORPROGB in the night lock or entrance only functions.
It is inhibited by manual selector DOORSELFB in the night lock function.
Can also operate as a closing only input (see sect. 7).
Terminals 10-11
= N.O. START input. Commands the door opening function and starts the initial set-up.
It is inhibited by digital selector DOORPROGB in the night lock function.
It is inhibited by manual selector DOORSELFB in the night lock function.
Can also operate in the stepping mode (see sect. 7).
●
TERMINAL BOARD M4
Connection to digital selector DOORPROGB. Use a 4-pole fl ex (0.5 mm in diameter), maintaining the same signal match between
selector and control unit. Maximum cable length 20 meters.
Route the connection cable well away from sources of electrical interference to prevent false displays on the selector.
Terminal 12 = 0 (powering negative)
Terminal 13 = DATA ITEM
Terminal 14 = +12 Vdc (powering positive)
Terminal 15 = G (ground)
Use the 4-pin terminal board in the DOORPROGB selector kit.
WARNING!
The DOORPROGB selector kit includes the “LOGIC TAST” interface board, which must be fi tted into connector J8 (see fi g. 2)
so as to allow the selector to work with the BRINK control unit.
●
TERMINAL BOARDS M5 - M6 = Dedicated to connection of photocell DOORFOTO2; see sect. 12 for operation mode.
●
TERMINAL BOARD M7
Terminals 16 (-)-17(+)
= 24 Vdc output, max. 20 W, for powering external accessories.
The line is protected by the 4A fuse F2.
Led L1 indicates that the line is powered.
●
TERMINAL BOARD M8
Terminals 18-19
= N.O. clean contact of relay RL1 that can be used to connect an electro-lock.
Take the power from terminals 16-17 in the case of a 24 V electro-lock.
Terminal 20
= Signal output of the OPEN COLLECTOR type, active when door is open or moving; max. load
100mA.
The positive signal is taken from terminal 17.
CONNECTORS J1-J2
= power transformer connection: primary on J1, secondary on J2.
CONNECTORS J4-J10
= wiring of signal conductors between electrical connection part CPB-1 and logic part LGN of the
electronic control unit.
CONNECTORS J5-J11
= wiring of powering conductors between parts CPB-1 and LGN of the control unit. The line is protected
by the 8A fuse F3.
CONNECTOR J6
= encoder connection.
CONNECTOR J7
= motor connection.
ELECTRONIC SECTION