10
K898M
English
•
MICROPROCESSOR-CONTROLLED LOGIC
•
DIAGNOSTIC LEDS
•
LINE INPUT PROTECTION WITH FUSE
•
INCORPORATED ELECTRONIC TORQUE LIMITER
•
ELECTRONIC PEAK LOAD CONTROL
•
INCORPORATED FLASHING LIGHT
•
CONNECTOR FOR RECEIVER BOARD
CONNECTION TO THE TERMINAL BOARD
1-2-3
motor output; 1 = opening phase; 2 = common; 3 = closing phase
4-5- 6
auxiliary motor output; 4 = closing phase; 5 = common; 6 = opening phase
7-8
power supply 230 Vac 50/60 Hz.
9-10
output for flashing light 230Vac
11-12
output for auxiliary courtesy light 230 Vac
13-18
input for open/close push button (normally-open contact): for usage, see the functions
of dip switches 2-3; 18 = Common
14-18
Stop push button NC (normally closed) contact. After a stoppage, the system always
starts again with an opening phase and only after receiving a command from the On
button or radio transmitter. 18 = Common
15-18
input for opening limit switch (normally closed contact); 18 = Common
16-17
input for closing limit switch (normally closed contact); 18 = Common
17-18
Input for pressure-sensitive edge (mechanical edge) or other safety devices, e.g.
photocells (NC contact); 18 = Common
19-20
24 Vac output for powering safety and/or other devices (photocells, mechanical edge,
relays for lighting, etc).
21-22
output for 2nd radio channel
Warning: to connect other devices to the 2nd Radio Channel (area lighting,
pumps, etc.), use an additional auxiliary relay.
23-24
input for radio aerial: 23 = braid, 24 = main cable
LOGIC ADJUSTMENTS TRIMMER
TL
Trimmer for adjusting operating time (5-120 sec), or the time the overhead door
takes to complete a maneuver. The count begins each time a command is given. It is
advisable to adjust the time to a few seconds longer than is really necessary.