1. - Run button. By pressing this button, the machine commences its operating
cycle automatically. If the guard is open, the machine will run while the button is
pressed. ONLY FOR CLEANING OPERATION.
2. - Stop button. By pressing this button, the work cycle of the machine is
stopped immediately. To reactivate the only thing that has to be done is to press
the previously mentioned Run button
3. - Photocell selector ON/OFF. This allows us to activate or deactivate the
safety photocell located at the entry point of the feeder module.
IMPORTANT: WHEN THE MACHINE IS IN OPERATION THIS
SELECTOR MUST BE IN THE ON POSITION. IF DEACTIVIATED AND THERE
WERE TO BE A FAILURE ON FEEDING A SHEET, OR THE PILE HAS
FINISHED, THE CALANDER WILL CONTINUE ROTATING AND THE PLASTIC
WILL STICK TO THE PRESSURE ROLLER, SO THAT WORK WOULD HAVE TO
STOP IN ORDER TO CLEAN THIS ROLLER, WHICH CAN BE PARTICULALRLY
DIFFICULT DEPENDING ON THE AMOUNT OF PLASTIC THAT WERE TO HAVE
ADHERED TO IT.
4. - Temperature selector ON/OFF. When this is ON the resistances are also
receiving current, provided the working temperature has not been reached and the