Turbomachinery Package Specification
Taurus
60 Compressor Set and Mechanical Drive
Offskid Control Console Dimensions
One-Bay Control Console
Height
2286 mm (90 in.)
Width
914 mm (36 in.)
Depth
800 mm (32 in.)
Approximate Weight
570 kg (1250 lb)
Two-Bay Control Console
Height
2286 mm (90 in.)
Width
1448 mm (57 in.)
Depth
800 mm (32 in.)
Approximate Weight
680 kg (1500 lb)
Supervisory Interface Modules
ControlNet 1.5
Cables RG-6U
Coaxial
Maximum Cable Length
1000 m (3300 ft)
Transmission Protocol
Common Industrial Protocol (CIP)
Transmission Speed
5 Mbps
Ethernet
Cables 10BaseT
Network Length
100 m (330 ft) To Nearest Hub
Transmission Protocol
CIP Protocol with TCP/IP
Transmission Speed
10 Mbps
Data Highway Plus
Cables
DH+ Twisted Pair
Maximum Cable Length
3000 m (10,000 ft)
Transmission Protocol
CIP or DF1 Protocol
Transmission Speed
57.6 bps
Modbus
Cables
RS232C, RS422, or RS485
Cable Length
RS232C: 15 m (50 ft)
RS422 and RS485: 1200 m (4000 ft)
Transmission Protocol
Subset of Modbus RTU Protocol
Package End Devices
Transmitters 4-20
mA
Switches 0-24VDC
Thermocouples Type
K
RTDs
100 ohm Platinum
Proximitors 3300XL
Solar’s Applicable Engineering Specifications
ES 9-56
Fusion Welding
ES 1593
Guidelines for NEC Compliance of
Solar
Product Lines: Class I, Group D, Division 1
and Division 2
ES 1762
Standards and Practices for Electrical Systems for Gas Turbine Packages Installed In
Hazardous Areas (CENELEC/IEC Standards – European ATEX Directive 94/9/EC)
ES 2231
Standards and Practices for The Design and Installation of Cable Channels and TC
Rated Cables Installed In Class 1, Division 2 Hazardous Areas
© 2009 Solar Turbines Incorporated. All rights reserved.
TPS60CSMD/309
43