10-15 seconds more after the burner has ignited. If
the pilot flame goes out when you release the knob,
repeat the above process.
Note:
•UPON first lighting a new heater, it may be neces-
sary to hold the control knob down for a longer time
in order to allow gas to flow to the pilot.
•Once the heater is alight at the 1-LOW setting, turn
the control knob to 2-MEDIUM or 3-HIGH position to
light the second and third panel respectively.
•UPON first lighting, panel 2 and 3 will take a little
longer to ignite. Be patient as this is normal.
• To turn off the heater, return the control knob to the
OFF position and close the GAS cylinder valve fully
(clockwise).The heater can only be turned off by
closing the cylinder valve. It cannot be turned off by
the control knob.
•
Changing the cylinder:
Turn off the cylinder valve fully (clockwise) and
allow the heater to cool fully before removing and
replacing the cylinder. Do not attempt to remove the
regulator while the heater is still running.
• The heater incorporates several safety devices
that will shut down the heater in unsafe conditions.
The first is that in case of accidental flame failure,
the gas heater will shut down automatically. The
second device will turn off the heater if it is tipped
over, if this activates, set the heater upright, check
for obvious damage and again wait 5-10 minutes
before attempting to re-light the heater. This device
may also operate if the heater is knocked against or
bumped.
IMPORTANT:
You should have purchased suitable
9kg gas cylinder for this heater. The cylinder will
require purging of air the first time it is filled, to
ensure correct operation of the heater. This should
be carried out by the gas filling station. Your cylinder
should be checked for safe operation each time
when it is filled by an authorized filling station.
3.2.3. Using the electric heater
•
IMPORTANT: The electric and gas heater cannot
be used together.
3.2.3.1. Plug the appliance into the mains power
socket.
3.2.3.2. Turn the heater on by selecting your desired
heat setting. Pressing the 1st switch will turn on the
first quartz tube on and pressing the 2nd switch will
turn on the remaining two quartz tubes.
4. Cleaning and maintenance
4.1. Disconnect the appliance from the mains power
supply before undertaking any cleaning task.
4.2. Before any cleaning task is performed, ensure
that the gas supply is completely turned off.
4.3. Ensure the heater has cooled down completely
before undertaking any cleaning task.
4.4. The heater should be checked for gas leaks
regularly.
4.5. Clean the outer parts of the appliance with a
damp cloth with a few drops of washing-up liquid
and then dry. CAUTION! Do not immerse electrical
parts of the appliance in any liquid.
4.6. Do not use solvents, or products with an acid
or base pH such as bleach, or abrasive products, for
cleaning the appliance.
4.7. Never submerge the appliance in water or any
other liquid or place it under running water.
5. Anomalies and repair
5.1. Take the appliance to an authorised support
centre if product is damaged or other problems
arise.
5.2. If the connection to the mains has been dam-
aged, it must be replaced and you should proceed as
you would in the case of damage.
For the other two quartz tubes
For top quartz tube
Summary of Contents for HIBRIDO 947183
Page 5: ......
Page 10: ...Troubleshoot Guide...