background image

13

          
      

The Power Supply

The power outlets for the ECO Controller for your system are located inside 
the Blower Box. Each switch must be in the ON position at all times.  If any or 
all switches are OFF, the treatment process and alarms may not function.
The single GPO is for the 240V – 12V power supply for your controller and the 
double GPO is for your Pump and Blower. The double GPO contains a 7amp 
breaker underneath the GPO, which will activate in the case of a fault with the 
pump and/or blower. If the breaker is activated it will trigger the associated 
alarm on the Controller. You can reset the Breaker by pushing in the reset 
button (see page 15 for full instructions). If the breaker is activated again, 
please contact your Service Agent to rectify the issue.

 

Normal Operation

RESET BUTTON

Circuit Breaker 

Activated / “Tripped”

Optional Extra

A 12volt In House Alarm Panel is 
available as an optional extra to the 
system. If required, the panel can be 
fitted during the installation of the 
system. The In House Alarm Panel 
is connected to the same circuit as 
the Alarm, situated on the system, 
and works in tandem with the same 
functions listed above. To mute the In 
House Alarm, press the red button, this 
will silence the alarm. The alarm at the 
system will still function, and needs to 
be muted separately. The LED light on 
the In House Alarm panel will continue 
to flash until the fault is rectified.

FIGURE (2)

Summary of Contents for Advanced Blower System

Page 1: ...1 Owner s Manual Taylex Advanced Blower System TAYLEX COM AU...

Page 2: ...aylex Systems produce the highest quality effluent for the safest and best environmental outcome Wastewater Recycling Systems for Australian New Zealand homes that protect your family and our environm...

Page 3: ...k What keeps my system healthy What upsets the balance Suitable Products Products to avoid Servicing your Wastewater Treatment System Operating Instructions for Eco Controller Help Troubleshooting Ala...

Page 4: ...who market install and service our range nationally in Australia and New Zealand Post installation we have a network of over 300 trained Service Technicians to provide the ongoing care and maintenanc...

Page 5: ...ged from the toilets and bidets and the sullage grey water that is discharged from sinks washing machines dishwashers showers and baths Your Taylex ABS treats wastewater in an environmentally sustaina...

Page 6: ...uld end and effluent would now be pumped onto your property and into our environment relying on sand or soil to do the rest With a Taylex Wastewater Treatment System there are still four more steps to...

Page 7: ...mber The water gets a kiss goodbye from our Chlorinator which removes any harmful bacteria viruses and pathogens Using less chlorine per litre than your average swimming pool the system removes any ha...

Page 8: ...h a Nitto air blower that takes fresh air and introduces it to the water through an aerator diffuser The oxygen in the air dissolves into the water as it bubbles up to the top This gives the water a h...

Page 9: ...rtain cleaning products as poisons if high levels are used Please always use environmentally friendly products Your treatment system relies on bacteria for it to work effectively therefore any product...

Page 10: ...and environmentally friendly Toilet fresheners are not recommended Floor Cleaners It is recommended to use hot soapy water to clean floors Using floor cleaners is generally acceptable at controlled l...

Page 11: ...aging to our environment than more traditional cleaning products When selecting cleaning products if in doubt always look for products that are phosphate free or low phosphate Too Much Of Anything Is...

Page 12: ...e sanitary products should never be flushed as they will not break down in your system Kitchen Related Products Avoid putting things such as dairy products cooking oils excess food scraps especially f...

Page 13: ...mmed and cut If you have a locked yard provide your service person with a key Make sure surface water does not pool and can never enter the tank even during torrential rain events Ensure that all coun...

Page 14: ...d AS NZS 3100 2017 meeting the Electrical Safety requirements in Australia and New Zealand Your Taylex ABS is designed to operate automatically and its operation will usually be event free The Eco Con...

Page 15: ...12 Flashing Fault detected Press to mute alarm for 24 hours Solid green Power is on...

Page 16: ...er by pushing in the reset button see page 15 for full instructions If the breaker is activated again please contact your Service Agent to rectify the issue Normal Operation RESET BUTTON Circuit Break...

Page 17: ...gation outlet filter blocked If fitted Resetting your system If you have identified an issue once it is fixed you can try resetting your system 1 Turn the system OFF remove the 4 screws on the Blue or...

Page 18: ...ng 1 Is there a filter on the irrigation line before the effluent disposal area Is it blocked 2 Is the irrigation line kinked or broken 3 Has the irrigation pump failed 4 Surface irrigation Are all th...

Page 19: ...3 Turn off both switches 1 Pump 2 Blower 4 Push in the reset button and wait 10 seconds 5 Switch on switch 1 and wait 10 seconds 6 Switch on switch 2 and wait 10 seconds 7 If the circuit breaker Trip...

Page 20: ...ect power supply or repair and or attempts to repair by unauthorised personnel The benefits conferred by this warranty are in addition to all other rights and remedies in respect of the product which...

Page 21: ...est Report No 90644 19 70 20 PP001 for ABS Controller to AS NZS 3100 2017 A1 A2 demonstrating compliance with essential safety requirements of AS NZS3820 ABS ECO Controller same as ABS Controller exce...

Page 22: ...19...

Page 23: ...20...

Page 24: ...21 www taylex com au 1300 TAYLEX Owner s Manual for the Advanced Blower System Taylex Australia Pty Ltd Your local distributor...

Reviews: