11
Indoor temperature unit setting
Users can adjust indoor temperature unit in this mode. Press
[+]
or
[-]
to toggle the temperature unit between ºF and ºC.
Indoor high temperature alarm setting
Users can adjust indoor high temperature alarm setting in this
mode. Press
[SET/HISTORY]
to allow or forbid indoor high
temperature alarm. Press
[+]
to increase the value of indoor high
temperature alarm, press
[-]
to decrease the value of indoor high
temperature alarm. Press
[+]
to increase the value of high
temperature alarm rapidly, press
[-]
to decrease the indoor high
temperature alarm value.
Indoor low temperature alarm setting
Users can adjust the indoor low temperature alarm setting in this
mode. Press
[SET/HISTORY]
to allow or forbid the indoor low
temperature alarm. Press
[+]
to increase the indoor low
temperature alarm value, press
[-]
to decrease the indoor low
temperature alarm value, press
[+]
to increase the indoor low
temperature alarm value rapidly, press
[-]
for to decrease the
indoor low temperature alarm value rapidly.
Maximum value of indoor temperature display
Users can view the history and time record of the maximum value
of indoor temperature. Press
[SET/HISTORY]
to clean up the history
record of maximum value.
Minimum value of indoor temperature display
Users can view the history and time record of the minimum value of
indoor temperature. Press
[SET/HISTORY]
to clean up the history
record of minimum value.
2. Indoor Temperature Mode
In normal mode, press
[MODE]
six times to enter
the indoor temperature mode. In this mode, users
can adjust settings related to indoor temperature.
Press
[NEXT]
to toggle the mode of parameters:
3. Outdoor Temperature Mode
In indoor humidity mode, press
[MODE]
to
enter the outdoor temperature mode. In this
mode, users can adjust settings related to
outdoor temperature. Press
[NEXT]
to toggle
the parameters setting mode: