background image

7

Horizontal 

Mount

Vertical /
Upright 
Mount

'AA'

'AA'

Short
Cord

Housing

Remote
Sensor

Mounting
Tube

Assembling Instructions

1.

 Properly align the compass and 

wind cup sensor together to create 
the wind base; do not press too 
hard otherwise damage may occur. 
Insert the connector tube to the 
bottom of the wind cup sensor and 
fasten with an M3x22 screw with nut 
(included).

2.

 Plug the shorter cord into the port 

located on the bottom of the wind 
cup sensor.

3.

 Thread the longer cord into the 

housing through the opening.

4.

 Connect the wind base and top of 

housing and fasten with an M3x22 
screw with nut (included). 

5.

 Remove battery compartment 

cover on the remote sensor and 
insert 2 AA batteries.  Replace 
battery compartment cover.

6. 

Connect the plastic mounting tube 

into the base.  Thread an M3x25 
screw with nut (included) through 
the aligned openings and tighten. 

7.

 Depending upon vertical or 

horizontal orientation, connect the 
transmitter to the plastic mounting 
tube and fasten together with an 
M3x18 screw (included). 

8. 

Plug the long cord from the housing 

into the port marked “Wind”.

9. 

Carefully slide the remote sensor 

with the mounting tube into the 
housing.

Note: The Wind Gauge 
Remote Sensor can be 
mounted in 2 different 
ways as shown here.

Summary of Contents for 2752N

Page 1: ...Instruction Manual Digital Wireless Weather Station with Dual Mount Wind Sensor Leading the Way in Accuracy 2752N...

Page 2: ...ore use and keep it handy for future reference Items included in this package shown on page 3 1 Base Station an indoor unit which displays temperature and other readings 2 Wind Gauge Remote Sensor an...

Page 3: ...3 Description of Parts mounting bracket Remote Wind Gauge Sensor Unit Base Receiver Unit Line 1 Line 3 Line 2 1 Line 4 9 10 8 Wind Sensor Cups Compass Wind vane...

Page 4: ...o select F or C temperature scale 8 Battery Compartments On back of Receiver Unit and on top of Wind Gauge Sensor base The Home Receiver unit uses 2 AAA batteries and Wind Gauge Remote Sensor uses 2AA...

Page 5: ...Time Alarm Current temperature base sensor location Current humidity base sensor location Current temperature remote sensor location Current humidity remote sensor location Current day Current date Cu...

Page 6: ...me Unit Receiver Batteries Important Install the receiver s batteries first before installing batteries in the Wind Gauge Remote Sensor 1 Remove the battery compartment cover located on the back of th...

Page 7: ...onnect the wind base and top of housing and fasten with an M3x22 screw with nut included 5 Remove battery compartment cover on the remote sensor and insert 2 AA batteries Replace battery compartment c...

Page 8: ...Note The effective range is vastly affected by the building materials and where the receiver and remote units are positioned Try various set ups for the best results Shorten the distance between recei...

Page 9: ...following picture The Wind Gauge Remote Sensor features five buttons MODE NEXT SET HISTORY There are 8 modes including Normal Mode Clock Mode Date Mode Indoor Temperature Mode Indoor Humidity mode Out...

Page 10: ...etting Users can adjust the hour of current time in clock mode Press to increase hour press to decrease hour press for increase hour rapidly press to decrease hour rapidly Minute setting Users can adj...

Page 11: ...decrease the indoor low temperature alarm value press to increase the indoor low temperature alarm value rapidly press for to decrease the indoor low temperature alarm value rapidly Maximum value of i...

Page 12: ...re alarm rapidly press to decrease the outdoor high temperature alarm value Outdoor low temperature alarm setting Users can adjust the outdoor low temperature alarm setting in this mode Press SET HIST...

Page 13: ...e wind speed Press NEXT to change the parameters setting mode 5 High wind speed alarm setting Users can adjust high wind speed alarm setting in this mode press SET HISTORY to allow or forbid high wind...

Page 14: ...tdoor low humidity alarm value press to decrease the outdoor low humidity alarm value press to increase the outdoor low humidity alarm value rapidly press to decrease the outdoor low humidity alarm va...

Page 15: ...low humidity alarm value press to decrease the indoor low humidity alarm value press to increase the indoor low humidity alarm value rapidly press to decrease the indoor low humidity alarm value Maxi...

Page 16: ...diagram shows the order of date display format Year setting Users can adjust the year setting in this mode press to increase the year setting press to decrease the year setting Press to increase year...

Page 17: ...y the party responsible for compliance could void the user s authority to operate the equipment Note This device complies with part 15 of the FCC Rules Operation is subject to the following two condit...

Page 18: ...to extremely severe temperatures 7 Do not clean either unit with abrasive or corrosive materials This may scratch plastic parts and corrode electronic circuits 8 Do not subject either unit to excessiv...

Page 19: ...from 12 to 12 user setting Daylight saving time is adjusted automatically The daylight saving time is adjusted on the basis of different time zone The date display format can be set as YYYY MM DD MM D...

Page 20: ...plaining reason for return to Taylor Precision Products Inc 2220 Entrada Del Sol Suite A Las Cruces New Mexico 88001 Customer Service Phone 1 800 225 4834 Customer Service Fax 1 575 526 4347 There are...

Page 21: ...digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses...

Reviews: