15
Models 340/341/342
Systems and Controls
Torque Control
Function/Operation
The thickness (and indirectly the temperature) of the
slush is controlled by a sensing device called the
Torque Switch. The refrigeration system is brought on
and off by a microswitch.
Inside the beater is a torque rotor to sense the
thickness of the product in the freezing cylinder. The
torque rotor should be inserted in the beater drive shaft
at the rear, and in the center of the door at the front.
When the beater turns, the moving product freezes
and exerts a clockwise pressure against the rotor as
the product thickens. This pressure is transmitted to a
torque arm, operating arm and spring.
When enough tension is produced, the microswitch is
tripped, breaking current to the holding coil of the
compressor; cycling the system off. As soon as the
compressor cycles off, the timer starts its 10 minute
timing period. When 10 minutes have elapsed, power
is sent through the timer to the solenoid. The solenoid
pulls the operating arm to the left, tripping the
microswitch. The microswitch sends power to the
holding coil of the compressor contactor; and the
system starts. When the product reaches serving
viscosity, the torque arm moves to the right, tripping
the microswitch, and the compressor stops. At this
time, the timer resets back to “0”.
When the draw handle is raised, the anticipator arm
assembly moves the torque arm to the left, tripping the
microswitch; starting the compressor.
11178
Figure 1
Adjusting the Torque Switch
To achieve a thicker slush consistency, turn the
adjustment knob
clockwise
. This will increase the
spring tension, making it more difficult for the torque
arm to overcome the spring tension to trip the
microswitch.
To achieve a thinner slush consistency, turn the
adjustment knob
counter--clockwise
, to decrease
the spring tension.
Summary of Contents for 340
Page 2: ......
Page 16: ...12 Introduction Models 340 341 342 Notes...
Page 18: ...14 Systems and Controls Models 340 341 342 Refrigeration System...
Page 27: ...23 Models 340 341 342 Parts Notes...
Page 28: ...24 Parts Models 340 341 342 340 Exploded View...
Page 30: ...26 Parts Models 340 341 342 340 Operator Parts Identification Model 340...
Page 32: ...28 Parts Models 340 341 342 120220 341 Exploded View...
Page 34: ...30 Parts Models 340 341 342 120220 341 Operator Parts Identification...
Page 36: ...32 Parts Models 340 341 342 120220 342 Exploded View...
Page 38: ...34 Parts Models 340 341 342 120619 342 Operator Parts Identification...
Page 41: ...37 Models 340 341 342 Parts 120814 Model 342 Beater Door A Self Closing Prime Plug Door...
Page 68: ...Models 340 341 049359 Rev 4 12...
Page 69: ...Model 341 049359 33 Rev 4 12...
Page 70: ...Model 340 341 049359 40 Rev 4 12...
Page 71: ...Model 341 049359 58 Rev 4 12...
Page 72: ...Model 342 052720 12 Rev 4 12...
Page 73: ...Model 342 052720 27 Rev 4 12...
Page 74: ...Model 342 052720 33 Rev 4 12...
Page 75: ...Model 342 052720 40 Rev 4 12...