1-4
TO THE INSTALLER
Model 632
To the Installer
1
Refrigerant
CAUTION!
In consideration of our
environment, Taylor uses only earth-friendly HFC
refrigerants. The HFC refrigerant used in this machine is
R404A. This refrigerant is generally considered nontoxic
and nonflammable, with an ozone-depleting potential
(ODP) of zero (0). However, any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER
fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion.
CAUTION!
Use only R404A refrigerant that
conforms to the AHRI standard 700 specification. The
use of any other refrigerant may expose users and
operators to unexpected safety hazards.
WARNING!
Refrigerant liquid sprayed onto
the skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush the area immediately with cold water. If burns are
severe, apply ice packs and contact a physician
immediately.
NOTICE!
Taylor reminds technicians to be
aware of government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory service department.
IMPORTANT! R404A refrigerant used in
conjunction with polyolester oils is extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
!
!
All manuals and user guides at all-guides.com