TO THE INSTALLER
1-3
Models C001 and C002
To the Installer
1
WARNING!
Avoid injury.
•
DO NOT
operate the machine unless it is
properly grounded.
•
DO NOT
operate the machine with fuses larger
than specified on the machine's data label.
•
All repairs should be performed by an
authorized Taylor service technician.
•
The main power supplies to the machine must
be disconnected prior to performing installation,
repairs, or maintenance.
•
For Cord-Connected Machines:
Only Taylor
service technicians or licensed electricians may
install a plug or replacement cord on the
machine.
•
Machines that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by the authorized personnel to
local codes.
•
Stationary machines that are not equipped with
a power cord and a plug or another device to
disconnect the appliance from the power source
must have an all-pole disconnecting device with
a contact gap of at least 0.125 in. (3 mm) in the
external installation.
•
Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
•
If the supply cord is damaged, it must be
replaced by the manufacturer, service agent, or
a similarly qualified person to avoid a hazard.
•
Secure supply cord ground lead to machine in a
location where if the cord is pulled the main
power leads become taut before the ground
lead can break loose.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
distributor for service.
Dasher (Beater) Rotation
NOTICE!
Dasher (beater) rotation must be
clockwise as viewed looking into the freezing cylinder. As
a safety feature, the dasher will not operate without the
freezer door in place.
Note: The following procedures must be performed
by a Taylor service technician.
To correct the rotation on a three-phase machine,
interchange any two incoming power supply lines at
freezer main terminal block only.
To correct rotation on a single-phase machine, change
the leads inside the dasher motor. (Follow the diagram
printed on the motor.)
Electrical connections are made directly to the terminal
block. The terminal block is provided in the control box
located behind the lower front panel.
Refrigerant
CAUTION!
This machine contains fluorinated
greenhouse gases (F-Gas) to provide refrigeration using
a hermetically sealed circuit or within foam insulation.
This machine's type of gas, quantity, Global Warming
Potential (GWP), and CO
2
tonnes equivalent information
is recorded on the machine's data-label. The refrigerant
used is generally considered nontoxic and
nonflammable. However any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER
fill any refrigerant cylinder completely with liquid.
Filling the cylinder approximately 80% will allow for
normal expansion
Summary of Contents for C001
Page 22: ...5 4 USER INTERFACE Models C001 and C002 User Interface 5 Notes...
Page 36: ...9 2 PARTS REPLACEMENT SCHEDULE Models C001 and C002 Parts Replacement Schedule 9 Notes...
Page 40: ...10 4 LIMITED WARRANTY ON MACHINES Models C001 and C002 Limited Warranty on Machines 10 Notes...