background image

Weekly Cleaning 

(continued)

 

 

©McDonald’s Corporation · Australia · Planned Maintenance Manual · Revised November, 2013 

Page 3 of 7

 

Ta

ylor Company Blended Ice Machine Model C029 - 

Australia 

Weekly 

BE  22 W1

14 

Additional pitcher cleaning. 

To remove film build-up on 
the inside of the blender 
pitchers, place the pitchers in 
the 3-compartment sink. Pour 
½ scoop of 

KAY Destainer 

into one pitcher. Fill the 
pitcher with warm water and 
allow it to soak for 5 – 10 
minutes. Wearing PPE 
gloves, brush clean to remove 
residual soil. 
 

Note: Use caution when 
cleaning the blender blade. 
 

 

Destainer 

 

 

 

 

Transfer the solution into the 
second pitcher and repeat the 
procedure. Once this is 
completed, discard the 
solution. Rinse and sanitize 
the pitchers in the 3-
compartment sink. Allow the 
pitchers to air dry. 

 

15 

Clean ice shaver assembly. 

Using the squeeze bottle of 
APC solution, flush the ice 
shaver assembly, while 
brushing with the large, white 
ice hopper brush. 

 

APC solution  

 

16 

Clean, rinse, and sanitize ice 
shaver assembly. 

Using the squeeze bottle of 

APC

 solution, flush inside, 

outside, and under the ice 
shaver assembly, thoroughly 
covering all surfaces. 
 

 

 

 

 

Flush the solution under the 
lip of the plastic cover. Make 
sure solution is applied in a 
complete 360° circle. 
 
Repeat Steps 15 and 16, using 
clean, warm water. 
Repeat Steps 15 and 16, using 
sanitizing solution. 

 

APC & Sanitizer solutions 

 

17 

Place buckets in front of 
machine. 

Place the three buckets on the 
floor in front of the machine. 
The bucket containing the 

APC

 cleaning solution will be 

used first. 

 

18 

Install cleaning tubes. 

Install cleaning tubes onto all 
inlet fittings. 
Place the other end of the 
cleaning tubes into the bucket 
of 

APC

 solution. 

 

APC solution 

 

19 

Re-install rinse station 
assembly and install cleaning 
hose. 

Slide the cleaning hose 
adaptor onto the dispensing 
head. Wedge the other end of 
the hose into the rinse station 
grate. 

20 

Open all CO2 valves. 

Turn all CO2 valves to the 

down/on

” position to open 

all the pumps. 

Summary of Contents for C029 Australia

Page 1: ...Tower Drain Cleaner Ice Scoop Brushes Squeeze Bottle Sanitized Towel Safety Glasses Spray Bottle Cleaning Tubes Weekly Cleaning Procedure 1 Press the MENU key to display the Main Menu screen Press th...

Page 2: ...iscard the ice into the back sink 9 Remove the ice hopper ice hopper cover splash guard and ice chute for cleaning 10 Remove additional parts for cleaning Blender pitchers Skirt Syrup rail Rinse stati...

Page 3: ...hile brushing with the large white ice hopper brush APC solution 16 Clean rinse and sanitize ice shaver assembly Using the squeeze bottle of APC solution flush inside outside and under the ice shaver...

Page 4: ...the sanitizing cycle Sanitizing solution After the solution stops pumping through the systems it will soak for 60 seconds 24 Remove cleaning tubes Remove the cleaning tubes from the bucket of sanitizi...

Page 5: ...bin shelves 32 Install the product Install the product bags into the product bins with the spout facing down Position the rear groove of the spout into the front slot of the product bin Make sure it s...

Page 6: ...der pitchers Lid holders Whipped cream holder and cover Syrup rail Skirt 40 Wipe machine clean Using clean sanitized towels and the spray bottle of KAY 5 Sanitizer wipe down the interior of the refrig...

Page 7: ...his helps prevent sputtering of solution and possible splashing back onto clothing or eyes Drain Cleaner 48 Carefully spray 1 4 of the solution into the blender dispensing area drain hole 49 Carefully...