17 - ENGLISH

7 TROUBLE-SHOOTING

7.1 ALARMS MANAGEMENT

The “OMEGA” electronic card is a powerful control logic unit which signals possible
machine troubles by means of alphanumeric messages visualised on the display; the
technician shall understand them to quickly find the reason of this trouble.

MESSAGE

DESCRIPTION

REMEDIES

EME

EMERGENCY

The door is open or the safety grid on the hopper is not

completely lowered.

An intermittent beep is released.

Make sure that the door

is closed and the safety

grid on the hopper is

lowered.

TER

MOTOR

THERMAL

CUTOUT ALARM

When a motor thermal cutout is triggered, it is followed by

the blinking of  the led TER and by the release of an

intermittent beep.

After checking the

machine, press STOP to

restore correct

functioning.

EPO

STORED DATA

ALARM

When the machine is started up, the microprocessor checks

the data stored in the EPROM  memory: if this data are not

correct EPO will appear on the display, followed by the

release of an intermittent beep.

Send for a technician.

EPI

MEMORY ALARM

If, during normal functioning, the memory is not

acknowledged, EPI will appear on the display, followed by

the release of an intermittent beep.

Send for a technician.

LI

POWER SUPPLY

ALARM

If, during normal functioning, the voltage is too low, LI  will

appear on the display, followed by the release of an

intermittent beep.

Check mains voltage

and machine power

supply.

OUT

USCITE MODULE

ALARM

If, during normal functioning, the output control module is

faulty or if it is not acknowledged, OUT  will appear on the

display, followed by the release of an intermittent beep.

Send for a technician.

TA

TA ALARM

If, during normal functioning, an anomaly of the current

transformer occurs, TA  will appear on the display, followed

by the release of an intermittent beep.

Send for a technician.

UTA

TA MICRO-

PROCESSOR

ALARM

If, during normal functioning, an anomaly of the

microprocessor controlling the consistency calibration

occurs, UTA  will appear on the display, followed by the

release of an intermittent beep.

Send for a technician.

Summary of Contents for C116

Page 1: ...EL D UTILISATION ET D ENTRETIEN MANUAL DE USO Y MANUTENCION MANUALE D USO E MANUTENZIONE ELECTRONIC HORIZONTAL BATCH FREEZER TURBINES LECTRONIQUES HORIZONTALES MANTECADORAS HORIZONTALES ELECTR NICAS M...

Page 2: ......

Page 3: ...1 ENGLISH...

Page 4: ...Distributor s stamp IMPORTANT We recommend to carefully and fully read the present manual before using your TAYLOR COMPANY machine In your own interest pay particular attention to the following warnin...

Page 5: ...improve its product or manual without prior notice and to insert them in the subsequent issues INDEX 1 TRANSPORT HANDLING AND STORAGE 4 1 1 Preliminary Inspection 4 1 2 Machine unpacking 4 1 3 Packing...

Page 6: ...d put it in a safe place Unscrew the machine side panels by means of a cross and or cut screw driver Turn out the screws fixing the packing lower side to the machine by means of a 17mm wrench Remove t...

Page 7: ...following indications Manufacturer s name and address Machine model and version Serial number Rated electrical characteristics Type and weight of employed Freon Manufacturing year Indication Points o...

Page 8: ...rs are expressly designed and engineered for ice cream batch freezing cycles and for the production of granita 3 2 LIMITS OF USE Never use the machine with variable supply voltage and or more than 10...

Page 9: ...eginning of batch freezing in case the consistency minimum value set up by the manufacturer is not reached The compressor stops the agitator runs slowly the STOP pushbutton is lit up the production pu...

Page 10: ...achine is in STOP position then turn the lever upward to unlock the door and turn it to the left 4 Water shower system It is equipped with a flexible pipe and it is used by the operator to wash the cy...

Page 11: ...ycles press STOP to decrease the selected value CLEANING INCREASE VALUE pushbutton This pushbutton has 2 functions 1 When the machine is in STOP function mode press CLEANING to start the agitator moto...

Page 12: ...evel of batch freezing independently of the kind of mixture used on condition that it is within the minimum and maximum quantities allowed for the machine capacity The following safety devices are all...

Page 13: ...an cause the malfunction of the machine and sometimes serious damages 5 3 1 AUTOMATIC CYCLE Place the cover back on the hopper to prevent dust and other impurities from getting in contact with the mix...

Page 14: ...display which visualises the last consistency value that had been set manually and the STOP CLEANING DELIVERY pushbuttons will light up The mchine is now ready to be programmed with a new ice cream co...

Page 15: ...me has elapsed the PRODUCTION pushbutton blinks and an intermittent beep is released Press the STOP pushbutton and deliver the product 5 4 2 GRANITA SICILIANA Sicilian style crushed ice drink In this...

Page 16: ...shing operations easier however they cannot prevent mould proliferation etc caused by insufficient cleaning TAYLOR COMPANY recommends cleaning the tank and the parts in contact with the product after...

Page 17: ...the drip drawer from the front panel and thoroughly wash it If the drip drawer contains some mxture the agitator stuffing box is leaking and shall be replaced 11 Lubricate the OR rings and the stuffin...

Page 18: ...e clearance between the pads and the cylinder is excessive the agitator is no more able to perfectly scrap the cooling cylinder walls resulting in an extention of batch freezing times To restore the m...

Page 19: ...ear on the display followed by the release of an intermittent beep Send for a technician EPI MEMORY ALARM If during normal functioning the memory is not acknowledged EPI will appear on the display fol...

Page 20: ...ly balanced The machine interrupts the batch freezing cycle after 16 and switches to STOP mode an intermittent beep is released and the agitator keeps working Alarm lack of growth in consistency the c...

Page 21: ......

Page 22: ...TAYLOR COMPANY 750 North Blackhawk Boulevard Rockton IL 61072 Telephone 815 624 8333 Telex 6871502 TAYLO Fax 815 624 8000 www taylor company com December 2002 Taylor All rights reserved cod M04 37530...

Reviews: