1-8
INTRODUCTION/SAFETY
Model C152 & C161
Introduction/Safety
1
General Installation Instructions
NOTICE!
Only trained, authorized service technicians
should install this machine. Failure to comply will void the
factory warranty.
The following are general installation instructions. For
complete installation details, please see the checkout
card.
IMPORTANT!
All wiring and plumbing must
conform to national and local codes.
Site Preparation
Inspect the area where the machine will be installed
before uncrating the machine. Make sure that all possible
hazards to the user and the equipment have been
addressed.
WARNING
! Only install this machine in a
location where its use and maintenance is restricted to
trained personnel. Failure to comply may result in
personal injury.
Air-Cooled Machines
Do not obstruct air intake and discharge openings.
Model C152 requires 4 in. (102 mm) of space on both
sides, and no space at the rear of the machine. Model
C161 requires 6 in. (152 mm) of space on both sides of
the machine, and no space at the rear.
Install the air deflector provided and place the rear of the
machine against the wall to prevent recirculation of warm
air. Minimum air clearances must be met to ensure
adequate air flow for optimum performance. Failure to
allow proper clearance and airflow may cause poor
freezer performance and damage to the machine.
For Indoor Use Only:
This machine is designed to
operate indoors under normal ambient temperatures of
70° to 75°F (21° to 24°C). The freezer has successfully
performed in high ambient temperatures of 104°F (40°C)
at reduced capacities.
WARNING!
This machine must
NOT
be
installed in an area where a water jet or hose can be
used.
NEVER
use a water jet or hose to rinse or clean
the machine. Failure to follow this instruction may result
in electrocution.
CAUTION!
This machine must be installed on
a level surface to avoid the hazard of tipping. Extreme
care should be taken in moving this machine for any
reason. Two or more persons are required to safely move
this machine. Failure to comply may result in personal
injury or machine damage.
Uncrate the machine. Inspect the machine for damage.
Report any damage to the Taylor factory immediately.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.
Installer Safety
IMPORTANT!
In all areas of the world, the
machine should be installed in accordance with existing
local codes. Please contact your local authorities if you
have any questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and service
of Taylor machines.
•
Only Taylor service personnel should perform
installation and repairs on the machine.
•
Authorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the industry
standards on lockout/tagout procedures before
beginning any installation or repairs.
•
Authorized service personnel must ensure that
the proper personal protective equipment (PPE)
!
!
INSTALL POTABLE WATER CONNECTION
WITH ADEQUATE BACKFLOW
PROTECTION TO COMPLY WITH
APPLICABLE FEDERAL, STATE, AND
LOCAL CODES.
!
!
Summary of Contents for C152
Page 4: ...ii 085592 S Notes...
Page 30: ...2 12 CONTROLS Model C152 C161 Controls 2 Notes...
Page 36: ...3 6 TROUBLESHOOTING Model C152 C161 Troubleshooting 3 Notes...
Page 39: ...PARTS 4 3 Model C152 C161 Parts 4 Notes...
Page 56: ...4 20 PARTS Model C152 C161 Parts 4 Notes...
Page 88: ...6 10 WIRING DIAGRAMS Model C152 C161 Wiring Diagrams 6 Notes...