13
Model C300
Important: To the Operator
2.
BEATER OVERLOAD
-- Beater motor is out on
overload. When this fault occurs, the machine
automatically turns off. The fault clears when
the condition is corrected.
FAULT DESCRIPTION
L: BEATER OVERLOAD
R: BEATER OVERLOAD
CLR
+ + +
SEL
3.
CHK REFRIG SYS PSI
-- Compressor is out on
high head pressure. When this fault occurs, the
machine automatically turns off. The fault clears
when the condition is corrected.
FAULT DESCRIPTION
L: CHK REFRIG SYS PSI
R: CHK REFRIG SYS PSI
CLR
+ + +
SEL
4.
THERMISTOR SHORT
-- One or both of the
barrel (freezing cylinder) thermistor probes are
faulty.
FAULT DESCRIPTION
L: THERMISTOR SHORT
R: NO FAULT FOUND
CLR
+ + +
SEL
5.
THERMISTOR OPEN
-- One or both of the
barrel (freezing cylinder) thermistor probes are
faulty.
FAULT DESCRIPTION
L: THERMISTOR OPEN
R: NO FAULT FOUND
CLR
+ + +
SEL
6.
SYRUP PRESS LOW
-- When the syrup out
indicator displays a lack of syrup, the unit will
enter a HOLD mode. At this time, no
refrigeration or product flow from the flow
control will be allowed. Only the beater will
operate. When the syrup is satisfied the unit will
refill the product tank, and then automatically
return to the AUTO mode. The fault message
and the warning tone will clear.
FAULT DESCRIPTION
L: NO FAULT FOUND
R: SYRUP PRESS LOW
CLR
+ + +
SEL
7.
CO
2
PRESSURE LOW
-- When the CO
2
out
indicator displays a lack of CO
2
, a 60 second
internal timer will start. If the CO
2
is not
replenished at the end of the 60 seconds, both
freezing cylinders will shut down and this fault
message will appear. Replenish the CO
2
and
the fault message and warning tone will clear.
FAULT DESCRIPTION
L: CO2 PRESSURE LOW
R: CO2 PRESSURE LOW
CLR
+ + +
SEL
8.
H
2
O PRESSURE LOW
-- When the water out
indicator displays a lack of water, a 60 second
internal timer will start. If the water is not
replenished at the end of the 60 seconds, both
freezing cylinders will shut down and this fault
message will appear. Replenish the water and
the fault message and warning tone will clear.
FAULT DESCRIPTION
L: H2O PRESSURE LOW
R: H2O PRESSURE LOW
CLR
+ + +
SEL
Summary of Contents for C300 NP
Page 51: ...Model C300 059540 27 4 11...
Page 52: ...Model C300 059540 33 4 11...
Page 53: ...Model C300 059540 40 4 11...
Page 54: ...Model C300 059540 58 4 11...